background image

© VALLOX • We reserve the right to make changes without prior notification.

TECHNICAL SPECIFICA

TION

• 1.09.353E
• 6.8.2008
• Model 3510
© VALLOX

Model 3510

Technical specifications

VALLOX 75 SILENT

for dwellings with an area of 40–80 m

2

VALLOX 95 SILENT

for dwellings with an area of 80–120 m

2

• Efficient sound insulation in the unit
• Sound silencing fan construction
• Ceiling mounting prevents sound from passing through

to the wall structures in the dwelling

• Supply and extract air ventilation with heat recovery
• Good filtering
• In-built heat recovery bypass for summer ventilation
• Versatile control alternatives
• Handy ceiling mounting plate – for simple and quick

mounting

• Service switch as standard

All models are available as R and L models

SILENT

Plate heat exchanger, efficiency approx. 60%
Summer / winter damper
Electric 500 W radiator or water radiator (VKL)
G 3 + F 7
G 3
52 kg
Door switch
Cooker hood PTX / PTXP, control centre 1992/1992 EK
or remote monitoring control centre 1993 YK
230 V, IP 34
105 W, 0,9 A + post-heating 2.2 A, 3.1 A in all
180 W, 1,6 A + post-heating 2.2 A, 3.8 A in all
105 W, 0,9 A
180 W, 1,6 A

Heat recovery
Heat recovery bypass
Post-heating
Filters

Weight
Service switch
Power adjustment

Input power
and data

Supply air
Extract air

VALLOX 75 SILENT
VALLOX 95 SILENT
VALLOX 75 SILENT VKL
VALLOX 95 SILENT VKL

Supply air
Extract air

Fans

VALLOX 75
SILENT

Supply air
Extract air

Fans

VALLOX 95
SILENT

105 W 

65 dm

3

/s

60 Pa

105 W 

75 dm

3

/s

75 Pa

180 W 

85 dm

3

/s

50 Pa

180 W 

95 dm

3

/s

75 Pa

VALLOX 75 SILENT
VALLOX 75 SILENT VKL

Models:

VALLOX 95 SILENT
VALLOX 95 SILENT VKL

The VALLOX SILENT models have been designed especially

for ventilation in individual dwellings in blocks of flats

and terraced houses.

Содержание 75 SILENT

Страница 1: ...changer efficiency approx 60 Summer winter damper Electric 500 W radiator or water radiator VKL G 3 F 7 G 3 52 kg Door switch Cooker hood PTX PTXP control centre 1992 1992 EK or remote monitoring cont...

Страница 2: ...welling 4 3 2 1 VALLOX 75 95 SILENT DIMENSIONS AND MAIN PARTS 2 2 Main parts Extract air fan Supply air fan Postheating radiator electric or water Heat recovery cell Outdoor air filter F7 1 2 3 5 4 6...

Страница 3: ...OX 75 95 SILENT Pressure loss in ducts Total pressure SFP Specific Fan Power guideline value 2 5 kw m3 s SFP Input power total W Air flow max dm3 s Pressure loss in ducts Total pressure SFP Specific F...

Страница 4: ...52 53 55 28 36 44 47 51 53 54 20 30 39 42 45 47 49 19 33 37 41 43 44 76 79 83 85 89 90 89 50 54 60 62 65 67 68 61 67 73 74 79 78 80 53 61 67 69 72 74 75 41 48 57 60 63 65 67 29 32 39 42 44 46 47 22 3...

Страница 5: ...summer position airflow through the cell is prevented and heat recovery bypass is activated REMOTE MONITORING CENTRE VALLOX 1993A ON OFF switch Operating status data to remote monitoring Transformer...

Страница 6: ...he flow of outdoor air to the unit The unit starts automatically as soon as the risk of freezing has passed The threshold temperature of the risk of freezing can be set at the thermostat J of the wate...

Страница 7: ...the front edge of the damper below the front edge of the collar When detaching the damper take the same steps in the opposite order Self actuated one way dampers are only used in VKL model units B C D...

Страница 8: ...of the electric radiator The overheat protector T2 of the radiator R is triggered and power supply to the heating unit is stopped if the temperature of the thermostat exceeds 80 C The overheat protect...

Страница 9: ...stops the unit when the temperature of water radiator goes below the threshold value preventing the risk of freezing in the water radiator This also causes self actuated one way dampers SP to close p...

Страница 10: ...1 L L N L 3 2 N INTERNAL ELECTRICAL CONNECTION OF THE HOODS N L VALLOX 95 75 COOKER HOOD PTXP A 27983 COOKER HOOD PTX 27983 HOOD Distribution panel L3 230 V 160 V 120 V 70 V L N 90 V 135 V 180 V 1 5...

Страница 11: ...internal electrical connection F1 Supply air fan F2 Extract air fan T1 Post heating radiator regulating thermostat 0 25 C Limitation T2 Defrost thermostat 5 C K Capacitor SS Safety switch Wire colour...

Страница 12: ...LENT 12 ELECTRICAL CONNECTIONS REMOTE MONITORING VALLOX 75 95 control through remote monitoring with control centre 1993 YK 2A VALLOX 1993A YK 2A VALLOX 75 95 REMOTE MONITORING CONTROL CENTRE DISTRIBU...

Страница 13: ...plate has to be fixed horizontally in order to ensure that the unit will be straight The outdoor air duct must be insulated against condensation also between the unit and the ceiling mounting plate S...

Страница 14: ...he pipe and its components Examples of condensing water connections Yli 600 n 100 n 100 Suction air COLLECTOR condensing water goes to the cellar Water seal at the lower end n 100 Suction air and fill...

Отзывы: