Valley Classic Control Panel
28
Operation
Starting The Machine Dry (Without Water)
Before Starting Machine
1. ALWAYS make sure that
vehicles, other equipment,
livestock and persons are
clear of the machine before
operation.
2. Place the WET/DRY switch
in the DRY position to
by-pass the low pressure
switch. See Figure 28-1.
3. If an optional engine shut-
down circuit is utilized, place
the Engine RUN/START
switch in the START posi-
tion. See Figure 28-1.
4. If applicable start the engine
generator.
Start The Machine
5. Turn the control panel main
disconnect switch to the ON
position. See Figure 28-1.
If the power is supplied by
an engine driven genera-
tor, adjust the RPM of the
generator until the voltmeter
reads 460 – 505 volts. DO
NOT EXCEED 505 VOLTS.
See Figure 28-1.
6. Place the FORWARD/RE-
VERSE switch in either the
FORWARD or REVERSE position. See Figure
28-1.
7. Set the percent timer to the desired speed set-
ting. See Figure 28-1.
8. Press and hold the START/STOP switch in the
START position for 3 seconds and release. The
machine should start. See Figure 28-1.
9. Place the Engine RUN/START switch in the RUN
position. See Figure 28-1.
OFF
ON
Classic
CAUTION
DO NOT HOLD BUTTON DEPRESSED
LONGER THAN 3 SECONDS. REPEATED
START ATTEMPTS CAN CAUSE SERIOUS
STRUCTURAL DAMAGE
4
3
6
2
5
8
1
7
9
Figure 28-1 1. Wet/Dry Switch
2. Run/Start Switch
3. Main Disconnect Switch "ON"
4. Voltmeter
5. Forward/Reverse Switch
6. Percent Timer
7. Start/Stop Switch
8. Stop In Slot Switch
9. Auto Reverse/Auto Stop Switch
10. If the machine is equipped with the optional stop-
in-slot mechanism, place the SIS ON/OFF switch
in the desired position. See Figure 28-1.
11. If the machine is equipped with auto reverse/auto
stop, place the AUTO REVERSE/AUTO STOP
switch in the desired position. See Figure 28-1.
12. If the machine is equipped with the optional Aux-
iliary ON/OFF switch to control an operation or
device, place the Auxiliary ON/OFF switch in the
desired position. See Figure 28-1.