Valley Classic Control Panel
20
Overview
Main Disconnect Switch
The main disconnect switch controls power to the
machine and has three positions, ON, OFF, and Test.
See Figure 20-1.
In the ON position, the control panel is on and power
is provided to the machine.
In the OFF position, the control panel is off and
power is disconnected from the machine. However,
incoming voltage to the control panel still exists on
the upper terminals of the main disconnect switch
inside the control panel.
The Test position is for use by service personnel only.
!
WARNING
• ALWAYS TURN THE MAIN DISCONNECT
SWITCH OFF, LOCK IT IN THE OFF POSITION
AND TAG IT WHEN DOING ANY MAINTE-
NANCE OR REPAIRS AND WHEN THE MA-
CHINE IS NOT IN USE.
Three Second Auto Restart
A three second auto restart function is built into the
circuitry of the control panel.
In the event of a momentary power loss or voltage
drop while the machine is running, the machine will
automatically restart if power is returned within three
seconds.
When the control panel also controls an irrigation
pump that is set to automatically start, the irrigation
pump must be protected with a pump restart delay.
!
CAUTION
• TO REDUCE THE POSSIBILITY OF DAMAGE
TO AN AUTOMATICALLY CONTROLLED
ELECTRIC PUMP DUE TO A MOMENTARY
POWER LOSS OF 3 SECONDS OR LESS,
A PUMP RESTART DELAY IS REQUIRED IN
THE PUMP CIRCUIT BETWEEN THE PIVOT
CONTROL PANEL AND THE PUMP.
CAUTION
DANGER
High Voltage!
480 Volts can kill.
Lock Machine Power
in the “OFF” position
before opening cover.
0997326
Do not operate system when temperature
is below 40° F (4.5° C)
Read and understand the valley operator
manual before operating this equipment.
CAUTION
0997300
CAUTION
DO NOT HOLD BUTTON DEPRESSED
LONGER THAN 3 SECONDS. REPEATED
START ATTEMPTS CAN CAUSE SERIOUS
STRUCTURAL DAMAGE
0997302
OFF
ON
TEST
Classic
1
2
Figure 20-1 1. Main Disconnect Switch
2. Test