180-PE1006 v1.11
October 3, 2018
Page 28
PE1006
OPERATING INSTRUCTIONS
DO NOT USE THE APPLIANCE WITHOUT A COMBUSTOR
RELOADING PROCEDURE (with the catalyst temperature in the ACTIVE ZONE)
1. Have your next load of wood ready before beginning. Turn the thermostat to
HIGH
and the fan(if fi tted)
OFF
. Wait 2 minutes for the air fl ow to stabilize.
2. Open the bypass door (rotate the bypass lever forward, on Princess Insert pull handle up) and again wait 2
minutes for the air fl ow to stabilize.
3. Unlatch the loading door and open just a crack to allow the ambient room air to be introduced to the
fi rebox, this may take a few seconds to stabilize.
4. Slowly open the loading door and proceed to reload the fi rebox. If you experience excessive smoke
spillage, slightly close the loading door to re-establish a draft through the chimney.
5. Once loaded, latch the loading door shut and close the bypass door (rotate the bypass handle backwards,
on Princes Insert push handle down). Let the fi re burn on the
HIGH
thermostat setting for 20 to 30 minutes
OR
until the fi re is very well established. At that point, turn the thermostat down to the desired setting.
Keep in mind you may not see a large amount of fl ame activity in the lower thermostat setting. The
thermometer needle will remain in the active zone indicating that the burn cycle is continuing.
6. Should you burn the stove on a very low setting for extended periods of time, you will begin to see
creosote deposits forming on the glass door. To remove these deposits, simple run the stove on
HIGH
for
approximately 30 minutes. The
HIGH
setting will burn off most of the deposits
As every pile of wood is diff erent you will learn, over time, which settings are necessary to achieve the optimal
fi re. This will be based on the type of wood, installation, weather conditions and the desired room temperature.
RELOADING PROCEDURE (with the catalyst temperature still in the INACTIVE ZONE)
Follow the procedure for “LIGHTING THE FIRE” on the previous page.
OPTIMAL THERMOSTAT SETTING
Any thermostat position between
LOW
and
HIGH
will produce the desired clean burning characteristics.
However, since each application can vary, you may fi nd it necessary to operate the thermostat to suit your
application. A thermostat setting on
HIGH
will produce a maximum heat which is more than suitable for
heating the average size home and off er the cleanest door glass.
1. Starting the fi re. Each stove, home, installation, chimney installation, and homeowner combination
works a little diff erently. The fi rst several times you fuel the stove, it may not react as you expect.
A little experimentation may be needed to fi nd the right combination of fuel and thermostat setting
to achieve the maximum effi ciency. This is one of the joys of burning wood. You, the wood burner,
make it work. And you can see what happens as it is working. Be patient, the air / fuel mixture and
temperature must be stabilized before maximum combustion effi ciency can be achieved.
2. As the combustor temperature (as indicated by the thermometer on top of the stove) passes into the
active zone, further adjustment to achieve the desired room temperature should be made in small
increments for the most eff ective cleaner burning operation. Changes should be made as few times
each day as possible. When the thermostat knob is moved from high to low, more gases are produced,
so the combustor has more fuel; consequently the combustor thermometer may register a higher heat
for several hours after the thermostat is turned down.
3. Keep hot coals active so when you reload the stove you will reduce the time necessary to maintain an
active combustor.
4. The thermostat is set at the factory.
DO NOT TAMPER WITH THE THERMOSTAT
, this will result in a
malfunctioning thermostat.
Содержание Blaze King PRINCESS PE1006
Страница 46: ...180 PE1006 v1 11 October 3 2018 Page 46 PE1006 REPLACEMENT PARTS Princess Classic PE1006BK...
Страница 47: ...180 PE1006 v1 11 October 3 2018 Page 47 PE1006 REPLACEMENT PARTS Princess Parlor PE1006LBK...
Страница 49: ...180 PE1006 v1 11 October 3 2018 Page 49 PE1006 REPLACEMENT PARTS...
Страница 50: ...180 PE1006 v1 11 October 3 2018 Page 50 PE1006 REPLACEMENT PARTS...
Страница 51: ...180 PE1006 v1 11 October 3 2018 Page 51 PE1006 REPLACEMENT PARTS Princess Classic Brick Layout...
Страница 52: ...180 PE1006 v1 11 October 3 2018 Page 52 PE1006 Princess Parlor Ultra Brick Layout REPLACEMENT PARTS...
Страница 57: ...180 PE1006 v1 11 October 3 2018 Page 57 PE1006 NOTES...
Страница 58: ...180 PE1006 v1 11 October 3 2018 Page 58 PE1006 NOTES...