background image

180-PE1006 v1.11

October 3, 2018

The authority having jurisdiction (such a municipal building department, fi re department, etc.) should be 

consulted before installation to determine the need to obtain a permit.

Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com

Manufactured By

Valley Comfort Systems Inc.

, 1290 Commercial Way, Penticton, BC, V2A 3H5, Canada

Phone: 250-493-7444 w Fax: 250-493-5833 w www.blazeking.com w [email protected]

OPERATION & INSTALLATION MANUAL

PRINCESS PE1006/PEJ1006

SOLID FUEL CATALYTIC STOVE

Installer: Please complete the details on the back cover

and leave this manual with the homeowner.

Homeowner: Please SAVE THESE INSTRUCTIONS for future reference.

This heater meets the 2015 U.S. Environmental Protection Agency’s particulate emission limits for wood heaters sold after May 15, 2015.

PE1006BK

PE1006LBK

PE1006UBK

Содержание Blaze King PRINCESS PE1006

Страница 1: ...Inc 1290 Commercial Way Penticton BC V2A 3H5 Canada Phone 250 493 7444 w Fax 250 493 5833 w www blazeking com w info blazeking com OPERATION INSTALLATION MANUAL PRINCESS PE1006 PEJ1006 SOLID FUEL CAT...

Страница 2: ...PE1006 and PEJ1006 14 COMBUSTION AIR 15 DRAFTING PERFORMANCE 15 ROLE OF THE CHIMNEY 15 VENTING SYSTEMS 16 RECOMMENDED FLUE HEIGHTS 19 MOBILE HOME AND RESIDENTIAL ALCOVE INSTALLATIONS 20 OPTIONAL ACCE...

Страница 3: ...CEMENT 38 BYPASS DOOR GASKET INSPECTION 38 BYPASS DOOR GASKET REPLACEMENT 39 DOOR GLASS GASKET INSPECTION 40 DOOR GLASS GASKET REPLACEMENT 40 DOOR GLASS CLEANING 40 LOADING DOOR TENSION ADJUSTMENT 41...

Страница 4: ...guard removed for servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modi ed This appliance must not be connected to a chimney ue pipe servicin...

Страница 5: ...plied with this heater is a Z4400G ceramic combustor Consult the catalytic combustor warranty also supplied with this wood heater Warranty claims should be addressed to in Canada in USA Blaze King Ind...

Страница 6: ...180 PE1006 v1 11 October 3 2018 Page 6 PE1006 APPLIANCE DIMENSIONS Princess Classic PE1006BK PRODUCT INFORMATION Z RSWLRQDO IDQV...

Страница 7: ...180 PE1006 v1 11 October 3 2018 Page 7 PE1006 APPLIANCE DIMENSIONS Princess Parlor PE1006LBK PRODUCT INFORMATION Z RSWLRQDO IDQV...

Страница 8: ...180 PE1006 v1 11 October 3 2018 Page 8 PE1006 PRODUCT INFORMATION APPLIANCE DIMENSIONS Princess Ultra PE1006UBK Z RSWLRQDO IDQV...

Страница 9: ...our passer au travers d un mur ou d un plafond ceci exige des m thodes sp ciales voir les directives et les codes locaux de b timent Estimation lectrique 115VAC 60 hertz 0 58 amp re risque de choc lec...

Страница 10: ...re to clean the ue When installed in a mobile home this appliance must be bolted to the oor and provided with outside air WARNING DO NOT INSTALL IN A SLEEPING ROOM CAUTION THE STRUCTURAL INTEGRITY OF...

Страница 11: ...and moved outdoors immediately If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Ot...

Страница 12: ...appliance ALSO DO NOT STORE COMBUSTIBLES UNDER THE APPLIANCE WOOD PAPER etc Contact local building o cials to obtain a permit and information on any installation restriction or inspection requirement...

Страница 13: ...tion or maintenance of the appliance and assumes no responsibility of any consequential damage s PARTS INCLUDED 1 Poker 2 Manual kit w warranty cards thermometer re starter bypass handle OPTIONAL EQUI...

Страница 14: ...ced corner Use side shields and either fan kit or rear shield 7 180 mm 21 535 mm 49 1245 mm Alcove roof exit Use side shields and either fan kit or rear shield 10 254 mm 6 153 mm 23 5 597 mm 16 25 413...

Страница 15: ...wall exits the same suggestion applies With the addition of the recommendation to use two 45 degree elbows rather than a single 90 degree elbow The use of two 45 degree elbows will allow for both a s...

Страница 16: ...liance To do so will a ect the safe operation of both appliances and will void the stove warranty You must comply with the local authority having jurisdiction and or in Canada CSA installation standar...

Страница 17: ...e are basically two methods of metal chimney installation One method is to install the chimney inside the residence through the ceiling s and the roof The other method is to install an exterior chimne...

Страница 18: ...resulting space must remain empty A ush mounted sheet metal cover may be used on one side only If covers are to be used on both sides each cover must be mounted on noncombustible spacers at least 1 c...

Страница 19: ...4 7 m 16 5 5 0 m 18 5 5 6 m 19 5 5 9 m 2000 3000 ft 610 914 m 16 4 9 m 17 5 2 m 19 5 8 m 20 6 1 m 3000 4000 ft 914 1219 m 16 5 5 0 m 17 5 5 3 m 19 5 5 9 m 20 5 6 2 m 4000 5000 ft 1219 1524 m 17 5 2 m...

Страница 20: ...e structure as recommended by the manufacturer Chimney connector must be double wall close clearance type with either ULC629 or ULCS610 designation Single wall pipe is not allowed in Mobile Homes or i...

Страница 21: ...COVES NOTE Fan Kit should be installed before the stove is placed into position ELECTRICAL CONNECTION Your Blaze King fan kit is equipped with a three prong grounded plug to decrease shock hazard THIS...

Страница 22: ...ss to stove bottom NOTE Use extreme caution when leaning the stove over to avoid injury or damage to the ooring or appliance 2 Remove four 1 2 bolts from bottom pan of appliance see Fig 1 3 Position e...

Страница 23: ...EAVY PLEASE HOLD FIRMLY INSTALLATION 1 Align bottom door hinge hole with bottom rebox hinge pin 2 Lower door onto bottom hinge pin then align top door hinge hole with top rebox hinge pin 3 Lower door...

Страница 24: ...approximately 10 minutes and then read the thermometer INTRODUCTION All Blaze King free standing wood appliances are designed as radiant room space heaters They have been designed and tested to be ins...

Страница 25: ...n this appliance but hardwood which is more dense will weigh more per cord and burn a little slower and longer Firewood should be split and stacked in a manner that air can get to all parts of it and...

Страница 26: ...ing contains between 19 25 water moisture included in the total calculated fuel weight Other test methods such as LHV or Low Heating Value does not take the water moisture into account Annual Fuel Uti...

Страница 27: ...rn with the thermostat in a HIGH setting for 20 30 minutes or until the re is well established At that point turn the thermostat down to the desired setting It is good burning practice to burn the sto...

Страница 28: ...installation weather conditions and the desired room temperature RELOADING PROCEDURE with the catalyst temperature still in the INACTIVE ZONE Follow the procedure for LIGHTING THE FIRE on the previou...

Страница 29: ...you may notice spillage this is when a small amount of smoke comes back into the living space When your re begins to warm the chimney and the draft improves spillage is greatly reduced After a short...

Страница 30: ...ombustor it may require cleaning or replacement It is also possible that the thermometer itself may not be reading accurately Before condemning the combustor read THERMOMETER If after cleaning has bee...

Страница 31: ...not functioning Solution Replace the combustor with a genuine Blaze King combustor failure to do so will void your warranty PROBLEM CATALYST PEELING Possible Cause Extreme temperatures above 1800 F o...

Страница 32: ...ge pieces to fall out replace the combustor PROBLEM MECHANICAL CRACKING Possible Cause Mishandling abuse or operating without a properly gasket sealed combustor Solution Handle with care Possible Caus...

Страница 33: ...lifting the shield o the two tabs at either side Pay particular attention to orientation as there is a top and bottom edge to the ame shield 2 Once you remove the ame shield you ll nd the combustor Th...

Страница 34: ...tor 5 This new combustor already has the gasket installed Note the 1 wide masking tape This tape will help to keep the leading edge of the gasket from snagging during installation If you ve cleaned yo...

Страница 35: ...as been installed you can relight your stove You will continue to receive excellent e ciency and clean burning for years to come A few reminders never burn anything other than dry seasoned cordwood Bu...

Страница 36: ...closed tightly 2 Call the local re department 3 Examine the chimney attic and roof of the house to see if any part has become hot enough to catch re If necessary spray with a re extinguisher or water...

Страница 37: ...ARBON MONOXIDE AND OR FLAMMABLE GASES THESE GASES MAY CAUSE SUFFOCATION AND POSSIBLE DEATH CHIMNEY MAINTENANCE The most e cient method to sweep the chimney is using a hard brush Brush downwards so soo...

Страница 38: ...ure the re is out and the stove has cooled down The door should be removed by lifting up and out o of the hinge pins Then lay the door at 3 With a pair of pliers pull the old door gasket out of the ch...

Страница 39: ...ve Looking down through the collar lift one end of the bypass door for clearance to turn inside the top assembly Once the bypass plate is in this position remove the plate through the combustor openin...

Страница 40: ...lso help Heavier deposits may require hand cleaning Manual glass cleaning should be done when the appliance and glass are cool DO NOT CLEAN THE GLASS WHILE IT IS HOT WARNING Do not use abrasive cleane...

Страница 41: ...ide Secure retainer nut and repeat paper test see LOADING DOOR GASKET INSPECTION Use penetrating oil if necessary to make turning easier DO NOT FORCE DO NOT OPERATE THIS WOOD STOVE IF THE DOOR GASKET...

Страница 42: ...s only an indication of the temperatures of the gasses after they pass through the combustor The thermometer probe the part that ts into the stove must be cleaned at least once a year Lift it from the...

Страница 43: ...our chimney and flue connector inspected by a certified chimney sweep A damaged masonry chimney should be repaired or rebuilt A prefabricated chimney factory built that is damaged should be replaced A...

Страница 44: ...ass door not sealing tightly Inspect by pass door and seal for warping Ash or creosote buildup may occur on door or seat With stove cold scrape and vacuum area around by pass Be sure all mating steel...

Страница 45: ...an oversize or short ue etc Measure draft with Manometer See DRAFTS Consult your Blaze King dealer or a chimney sweep Obstruction in chimney or cap screen Remove obstruction Clean chimney and or cap s...

Страница 46: ...180 PE1006 v1 11 October 3 2018 Page 46 PE1006 REPLACEMENT PARTS Princess Classic PE1006BK...

Страница 47: ...180 PE1006 v1 11 October 3 2018 Page 47 PE1006 REPLACEMENT PARTS Princess Parlor PE1006LBK...

Страница 48: ...180 PE1006 v1 11 October 3 2018 Page 48 PE1006 REPLACEMENT PARTS Princess Ultra PE1006UBK Princess Ultra PE1006UBK...

Страница 49: ...180 PE1006 v1 11 October 3 2018 Page 49 PE1006 REPLACEMENT PARTS...

Страница 50: ...180 PE1006 v1 11 October 3 2018 Page 50 PE1006 REPLACEMENT PARTS...

Страница 51: ...180 PE1006 v1 11 October 3 2018 Page 51 PE1006 REPLACEMENT PARTS Princess Classic Brick Layout...

Страница 52: ...180 PE1006 v1 11 October 3 2018 Page 52 PE1006 Princess Parlor Ultra Brick Layout REPLACEMENT PARTS...

Страница 53: ...End User except as noted for replacement parts Warranty Period Components Covered Parts Labor Wood 1 Year X All parts materials and surface nishes aking and peeling Subject to Conditions Exclusion and...

Страница 54: ...iginal purchaser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are se...

Страница 55: ...s Limited Warranty contact your authorized Blaze King dealer before installation 8 Blaze King will not be responsible for inadequate performance caused by environmental conditions 9 The Limited Warran...

Страница 56: ...rent retail cost of the repair or the replacement according to the year after purchase in the which the defect is brought to the attention of Blaze King During the 2nd year purchaser pays 20 3rd year...

Страница 57: ...180 PE1006 v1 11 October 3 2018 Page 57 PE1006 NOTES...

Страница 58: ...180 PE1006 v1 11 October 3 2018 Page 58 PE1006 NOTES...

Страница 59: ...180 PE1006 v1 11 October 3 2018 Page 59 PE1006 NOTES...

Страница 60: ...______________________________________ Installer print _______________________________________________________________ Installer sign _______________________________________________________________ Ph...