INSTALLATION OF DOOR/GATE STATIONS
Depending on the type of wall to which the station is to be affixed i.e. timber
or brick, installation is much the same as for room stations.
Where stations are exposed to extreme weather, a weather proof cover should
be fitted.
Green and orange wires are not used at door station. Tape green and orange
wires back to white outer sheath of valet cable.
Do not connect green and orange wires of door station cable at room station
end. Tape back in same manner as above.
Where a door station is part of a wiring loop, the door station should always
be the last station on the loop.
POS
NEG
COM1
COM2
TC
VLC
SHLD
CH
VR3
VR2
VR1
U5
SEL
PROG
RED
BLACK
WHITE
BLUE
SHIELDED GREY
SHIELDED YELLOW
DRAIN WIRE
GREEN
ORANGE
Green and Orange to be taped back
at this end and also at other end.
DOOR STATION - CABLE TERMINATION
NOTE: Drain Wire should
be insulated.