14
INSTALLATION OF VR102 ROOM STATIONS
Room Stations in Timber Frame Walls
Cut hole in wall lining keeping one side of the cut out adjacent to a stud so as
to allow for firm fixing.
Fit room station housing into cut out and mark positions for wall fixing
attachments. Remove housing and cut out a 3/16” – 1/4” vee for the fixing
point of the wing toggle bolt.
Pull any cabling through the room station back housing and fit the back housing into the
cut out hole securing it with the fixing attachments provided.
Strip back the outer white covering of the cable (approximately 3”), then strip the individual
wires (approximately 1/4”).
Firmly fix all bare wires into the appropriate screw terminals. Ensure bare wire from one
terminal does not touch the bare wire of another. (See diagram page 17)
Secure the front fascia onto the back housing using the four 1/2” screws
provided.
NOTE: It is suggested that these screws be only partially screwed in until
system has been fully tested.
Room Stations in Cavity Brick Walls
Remove the brick and mortar and insert the wall box ensuring that all cables
are first pulled the holes in the rear of the wall box.
Installation is then the same as for timber frame walls except for using
another wood screw instead of the wing toggle bolt. (See diagram page 16)