The pump can be connected to any shock-proof plug which has been installed according to
regulations ,The plug must have a supply voltage of 230V
~
50Hz.Fuse min.6Amp.
Caution
!
When the pump is to be used near swimming poor or garden pond sand in their area of protection, it
must be equipped with a ground-fault circuit interrupter with a nominal trip current of max.30mA
(according to VDE 0100,part 702 and 738).
The pump must not be operated while people are in the swimming poor or in the garden pond
!
Please
contact your electrician
!
Attention
!
(Important for your own security)Before starting running your new submersible pump, please have the
following items checked by an expert:
Ground connection
Zero conductor
Fault current breaker switch must correspond the safety regulations of the power plants and they
must work faultlessly.
The electrical connections must be protected from moisture.
If there is danger of loading, the electrical connections must be taken to higher ground.
Circulation of aggressive fluids, as well as the circulation of abrasive materials must be avoided at all
costs.
The submersible motor-driven pump must be protected from frost.
The pump must be protected from running dry.
Access on the part of children should also be prevented with appropriate measures.
The pollution of the liquid may occur due to leakage of lubricants.
Consistency
Your submersible pump is designated for the circulation of water with a maximum temperature of 35
℃
。
This
pump may not be used for other fluids, especially motor fuels, cleaning fluids, and other chemical products
!
Installation
The submersible motor pump is installed as follows:
In a stationary position with fixed pipeline
Or
In a stationary position with a flexible hose pipe
Please note
!
You should never install the pump by suspending it unsupported from its delivery pipe or power cable.
The submersible motor must be suspended from the specially provided handle or be place on the bottom of
Содержание 42285
Страница 1: ...ORIGINAL INSTRUCTION MANUAL SUBMERSIBLE PUMP 4606WP004DR 42285 Before start up note the following...
Страница 6: ...Hose connection 1 5 4 3 2 threaded end Foreign bodies up to Dia 25mm...
Страница 8: ...40 cable compaction board 1 40 1 41 screw 3 41 3 0406WP004DR 42285 230V 50Hz...
Страница 9: ...6Amp 30mA VDE 0100 702 738 t 35...
Страница 10: ...40 40 50 230V 50Hz 6Amp 230V 50Hz...
Страница 11: ...1 2 3 4...
Страница 12: ...35 1 2 3...
Страница 13: ...4 5 0406WP004DR 230V 50Hz 400Watt 7500 5 5 35 1 5 4 3 2 25...