501
Thermo H plus
5 Troubleshooting
5
Troubleshooting and error correction
5.1
General
This section describes troubleshooting and error correc
-
tion for Thermo H plus 160, H plus 230, H plus 300 and H
plus 350 heaters.
The safety information and regulations (see
) must
be observed.
5.2
HV heater troubleshooting
The following table lists possible, general error symptoms.
Danger to life and health!
Warning!
Table 501: Error symptoms and possible causes
Error symptom
Possible cause
Heater can not be switched on.
• Missing or insufficient supply voltage (24V)
• 24V fuses defective or not active
• Supply lead to the plug contacts of the HV control
wiring harness (24V) defective or contact not
established
• Plug of the temperature sensors not connected
• Temperature sensors defective
• HV small distribution board defective
• HVIL (Interloop) – failure (if existent)
Temperature in the water circuit too low / too high
• Control thermostat defective
• Diodes in LV wiring harness defective (if applicable,
heater may be connected incorrectly)
Heater can not be switched off.
• Supply voltage (24V) not switched off
• HV small distribution board defective
• Diodes in LV wiring harness defective (if applicable,
heater may be connected incorrectly)
Heater does not heat
• No HV supply connected / active
• HV fuses defective or not active
• Ground fault interrupter or insulation monitoring
device (IMD) defective or not active
• HV small distribution board defective
• Heating cartridge(s) defective