2 Technical data
Optional Fuel Filter Heater
NOTE:
Circulating pumps must be assigned to the heaters accor-
ding to the flow resistance in the coolant circulation sys-
tem.
2.1
Fuel
Suitable fuel is the diesel fuel specified by the vehicle ma
-
nufacturer. Only the on the model plate of the heater spe
-
cified fuel must be used.
The following table lists the by Valeo approved fuels and
their specifications.
*
Further information on approved by Valeo fuels con-ta
-
ins the TI (Technical Information) Fuels.
It can be found on the Valeo homepage under Service/
Technical Updates (TI)/Heating systems.
In case of air temperatures below 0°C a commercial avail-
able winter Diesel fuel must be used.
The usage of flow improvers respectively additives is per
-
mitted. There are no negative influences due to additives
known.
ATTENTION:
While using the fuels, their operating limits must be
considered and if necessary, suitable measures
(nozzle preheating, electrical heated filter) should be
applied.
If fuel is supplied from the vehicle tank, follow the
vehicle manufacturer’s instructions on additives.
Diesel part
Thermo H plus
160
230
300
350
Heating flow (at ambient
temperature of 20°C )
kW
kcal/h
16
13800
23
20000
30
26000
35
30000
Fuel
Diesel
Fuel consumption
kg/h
1.6
2.5
3.0
3.6
Rated voltage
V
24
Operation voltage range
V
20 - 30
Electrical power consumption at 24V
W
65
60
90
120
Max. permitted temperature of sucked
combustion air
°C
+85
CO
2
in exhaust gas at rated voltage
Vol %
9.5 + 1.0
9.5 + 1.5
Filter heater
Rated power consumption W
240
Rated voltage
V
24
Switch-on point
C°
0.5 ± 2.5
Switch-off point
C°
5.5 ± 2.5
Fuel
Requirements
acc.
Summer diesel
DIN EN 590
Winter diesel
DIN EN 590
Arctic diesel and Diesel for a strong
winter climate
DIN EN 590
Bio diesel (FAME)
*
DIN EN 12214
Paraffinic diesel fuel from synthesis
or hydrogenation (HVO)
*
DIN EN 15940
Содержание Thermo H 160