Thermo E+ 120/200/320
5 Troubleshooting
Manual inspection
•
Remove burner (see
•
Unplug the nozzle block preheater connector from the
control device.
•
Remove the nozzle block preheater as required.
•
Measure the resistance with an ohmmeter on the
wires that come directly from the heating element (one
measuring tip on the plug, another measuring tip on
the thermostat - contact to the heating element).
Limits:
12V Version: 1..3 Ohm
24V Version: 5..8 Ohm
•
Install the nozzle block preheater as required.
•
Reconnect the nozzle block preheater to the control
device.
ATTENTION:
When connecting, danger of confusion with the
electronic ignition unit (see
•
).