background image

BUS BODY ELECTRONICS

 

 

1.5  Overview of modes 

The SC600 contains 2 different modes 

– the operating mode and the  

fault mode. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 3 - SC600 Overview of modes 

SC600 

Operating  mode:

 

Includes  all  of  the 

functions  and  notes 

summarised  under 

point  2  except  for 

the    fault    readout 

and refill mode. 

The  normal  operat- 

ing  display  includes 

all  of  the  elements 

pictured  in  the  ex- 

ample: 

 

Fault 

readout 

mode  

Mode for displaying 

all  of  the  occurring 

faults  and  their  fre- 

quency  of  occur- 

rence. 

For 

more 

infor- 

mation, see points 

2.6.1 and 2.6.2. 

The  normal  fault 

display  includes  all 

of the elements pic- 

tured in the exam- 

ple:

Содержание SC600 Revo Global

Страница 1: ...Rev 21 11 2018 Id No DOK30629 BUS BODY ELECTRONICS SC600 REVO GLOBAL Operating Instructions Busdriver ...

Страница 2: ... 4 1 5 Overview of modes 5 2 Operation 6 2 1 Switching on off 6 2 1 1 Switching on 6 2 1 2 Switching off 6 2 2 Auto mode 6 2 2 1 Activation 6 2 2 2 Deactivation 6 2 3 Setting the blower manually 7 2 3 1 Activating the manual adjustment 7 2 3 2 Set blower level 7 2 4 Fresh air circulation function 8 2 5 Dehumidification 8 2 6 Setting temperature 8 2 7 Faults 9 2 7 1 Fault readout mode 9 2 7 2 Fault...

Страница 3: ...mode activated heating mode 6 Fig 8 SC600 auto mode deactivated 7 Fig 9 Manually adjusting SC600 blower level 7 Fig 10 SC600 Circulation function activated 8 Fig 11 SC600 dehumidification is activated 8 Fig 12 adjusting SC600 temperature 8 Fig 13 SC600 Faults 9 Fig 14 Entering SC600 access code Fehler Textmarke nicht definiert Fig 15 Reading out SC600 faults 9 Fig 16 Standard SC600 operating displ...

Страница 4: ...s of an operating element integrated into the dashboard control device as human machine interface and a rooftop air conditioning unit or floor heating The rooftop A C unit depending on the version takes over ventilation cooling and heating functions In addition air conditioning components can be controlled completely automatically In this case the bus driver only needs to set the desired temperatu...

Страница 5: ...play screen 1 Display 2 On off button 3 Scroll UP menu key 4 Scroll DOWN menu key 5 Function status light 6 Blower button 7 Fresh air circulation air button 8 Auto button A Inside temperature target value B Manual blower level C Cooling mode D Heating mode E Circulation air on F Fault display G Auto mode active H Outside temperature 1 2 3 4 6 7 8 5 Fig 1 SC600 dashboard B H C A D F G E ...

Страница 6: ...ons and notes summarised under point 2 except for the fault readout and refill mode The normal operat ing display includes all of the elements pictured in the ex ample Fault readout mode Mode for displaying all of the occurring faults and their fre quency of occur rence For more infor mation see points 2 6 1 and 2 6 2 The normal fault display includes all of the elements pic tured in the exam ple ...

Страница 7: ...bol in display light up Fig 5 2 2 2 Deactivation Press button in activated auto mode Mode is deactivated corresponding status light and function symbol are off Fig 8 Note Switching on system takes place only when the ignition is switched on is activated Note If the auto mode is activated the system automatically switches on cooling mode and heating mode as re quired Fig 6 and 7 Fig 4 SC600 Start d...

Страница 8: ...an be set to various levels from 0 blower speed 0 to 10 blower speed 100 Press button Blower level 1 Press button Blower level 1 Note When auto mode is deactivated the A C compressor and heater will switch off the former after a max after run period of 90 secs The blower is automatically adjusted if the blower level is not set automatically Note Adjustment can be made within the permitted limits e...

Страница 9: ...aching the desired temperature Pressing the button again within 10 minutes leads to switching the function and resetting to 10 minutes 2 5 Dehumidification Press button for 2 seconds Air dehumidification activated Fig 11 2 6 Setting temperature Press button Target temperature 1 C Press button Target temperature 1 C Note If the fresh air flaps are closed the corresponding status light lights up Fig...

Страница 10: ... Fault code Component Cause Remedy F001 Operating element Internal fault Replace ECU F017 Ice sensor Sensor defective Cable harness defective Examine cable har ness Replace sensor F018 Duct temperature sensor Sensor defective Cable harness defective F019 Interior temperature sen sor Sensor defective Cable harness defective F020 Ambient temperature sen sor Sensor defective Cable harness defective F...

Страница 11: ...r defective Coolant level too low Solenoid valve defective Pressure switch defec tive Expansion valve defec tive Examine axial blo wer Check coolant filling level Examine sensors Check for leaks Replace solenoid valve Replace pressure switch Replace expansion valve F026 Ice sensor Icing Temperature too low Wait until sensor is thawed out F033 Configuration fault Incompatible parameters selected Ch...

Страница 12: ...Valeo Thermal Commercial Vehicles Germany GmbH Postfach 1371 82198 Gilching Germany Tel 49 0 8105 7721 0 Fax 49 0 8105 7721 889 www valeo thermalbus com service valeobus valeo com ...

Отзывы: