5. Repairs 

5.1 Simple faults 

 

Fault 

Possible cause 

Remedy 

The fryer is no longer heating.  
No lamp lights up 
 
The red lamp lights up 

 

  No power 

 

  Safety thermostat has 

switched off 

 

 

  Check fuses, plugs and socket 

 

  Press reset button (see 5.3) 

The fryer is not heating 
sufficiently 

  One phase is missing on 

the power supply cable 

  Check fuses 

The fryer is not heating 
sufficiently 

  The switch has remained 

on "Melt" 

  Turn button to "Fry"

 

 

Oil cock is sticking 

  Sticking due to old oil 

residues 

  Actuate frequently with hot oil. 

i.e. filter oil daily 

 

The special mains cable must only be replaced by the manufacturer or his customer service 
representative.

 

5.2 Complex faults 

 

Fault 

Possible cause 

Remedy 

The signal lamps come on, but 
the fryer is no longer heating 

  Heating element defective 

  Call the service centre * 

The 

fryer 

is 

not 

heating 

sufficiently 

  Interruption of a phase 

  Heating element defective 

  Call the service centre * 

The fuses blow when fryer is 
switched on 

  Short-circuiting 

  Call the service centre * 

The fault current safety switch 
(FI) in the fuse box switches off 

  Moisture or poor insulation 

in the electrical circuit 

  Call the service centre * 

The colourless signal lamp does 
not come on or is flashing 

  Main switch defective 

  Call the service centre * 

The yellow signal lamp does not 
come on or is flashing 

  Thermostat defective 

  Call the service centre * 

The green signal lamp does not 
come on or is flashing 

  Thermostat defective 

  Call the service centre * 

 
 

* Important:

 

If you call the customer service dept, 

 

you must give the following information: 

 

 

Example: 

 

- Type of fryer 
- Unit no. 
- Volts, amps, kilowatts 

- V250 
- U253A111K3 
- 3x415V, 10.5A, 7.5kW 

 
 

You will find this information on page 1 of these instructions and on the fryer rating plate. 

 

If the information is correct the fitter gains time, the customer saves money! 

 

Содержание 2000 Series

Страница 1: ...nformity Valentine Fabrique SA 6 Avenue d Epenex CH 1024 ECUBLENS T l 41 21 637 37 40 Fax 41 21 637 37 41 Internet www valentine ch Mail info valentine ch confirms that the above mentioned products co...

Страница 2: ..._____ 5 4 Instructions for use_____________________________________________________ 7 4 1 Pouring in oil ________________________________________________________________ 7 4 2 Operation Melting Frying...

Страница 3: ...contact with the hot oil otherwise the oil will spatter Ensure that your face is not near the oil pan when food is immersed in it Beware of clouds of steam and hot oil spray Never allow anything but f...

Страница 4: ...y must be installed between 2 units of furniture or they must be supported on the sides 3 1 Electrical connection Only experts may connect and commission the fryers Your mains data voltage current fus...

Страница 5: ...ichbox IP X5 N B The V200 and V250 fryers which are only 200 and 250 mm wide respectively must be secured on the sides risk of tipping over A Steam extractor F Wall socket IP X2 B Wall G Connecting ca...

Страница 6: ...Oil cock lever 9 Colourless control lamp frying 27 Filter 10 Thermostat behind door 28 Discharge tank 11 Yellow control lamp heating 29 Thermostat sensor on heating element 12 Green control lamp immer...

Страница 7: ...s on immerse basket Set timer e g 3 minutes As soon as the timer sounds raise basket shake and suspend After half the frying time raise and shake basket Do not knock against oil pan Always top up with...

Страница 8: ...osition L Drain oil remove tank and clean filter Do not lift heating element fully otherwise oil will run along the rod to the heating element box additional cleaning Pour boiling water with a degreas...

Страница 9: ...ting Heating element defective Call the service centre The fryer is not heating sufficiently Interruption of a phase Heating element defective Call the service centre The fuses blow when fryer is swit...

Страница 10: ...without oil of improper use if the oil level is too low if you drain the oil before switching off the fryer If the heating element is not in the correct position in the oil pan if a block of fat is me...

Страница 11: ...S21 16A Safety switch XP 52 2 2 4 4 2 2 4 4 4 4 6 6321 S5 S10 16A Main switch 10A 42 04000 021 1 2 1 2 1 1 1 631652 S30 10A Main switch 16A 43 34832 003 1 2 1 2 631751 S40 S41 16A Connection terminal...

Отзывы: