5.3 Safety thermostat
Every heating element is fitted with a breakage-proof temperature limiter. The reset button is located
behind the door on the upper edge of the control panel. (Fig 5, no. 16, page 6). The red signal lamp
[19] to the right of the reset button lights up as soon as the temperature limiter switches off.
The safety thermostat
∗
when oil temperature is over 230
o
C
breaks the heating circuit
∗
when capillary tube is damaged
∗
when temperature drops below 0
o
C
and also in the case
∗
if fryer is heated without oil
of improper use
∗
if the oil level is too low
∗
if you drain the oil before switching off the fryer
∗
If the heating element is not in the correct position in the oil pan
∗
if a block of fat is melted on the heating element
Resetting the safety thermostat
Before resetting, find out why it has switched off (see above list).
- Allow fryer to cool.
The thermostat sensor on the heating element cannot be switched on if it
has not cooled down (to accelerate cooling raise heating element to the drain position).
- Push the red button [16].
Lamp [19] will go out.
N.B. Fryer is heating!
If the safety thermostat
switches off again the fryer must be switched off. Inform the service centre.
5.4
Safety switch
As soon as the heating element is raised to the "drain" position the safety switch (Fig. 5, page 6, no.