Compa II series
Options
07.15 Operating
manual
63
Press key
to arrive the next parameter.
On:
The start signal for the next label can already be released during
printing the current label. The signal is registered from the printer. The
printer starts printing the next label immediately after finishing the
current one. Therefore time can be saved and performance be
increased.
Off:
The start signal for the next label can only be released if the
current label is printed to the end and the printer is again in 'waiting'
state (output 'ready' set). If the start signal was released already
before, so this is ignored.
Press key
to arrive the next parameter.
Selection of the available configurations
Std_Label
(factory setting) or
StdFileSetLabel
.
1
Print start and cut (Input)
2
Reprint last printed label (Input)
3
Counter reset (Input)
4
Option applicator only:
Start application (Input)
5
Error reset (Input)
6 No
function
7 No
function
8 No
function
9 Error
(Output)
10
Print order active (Output)
11 Dispenser
photocell:
Label exists at dispenser photocell (Output)
12 Printing
(Output)
13 Ready
(Output)
14
Option applicator only:
Ready for application (Output)
15 No
function
16
Transfer ribbon prior warning (Output)
Save signal
I/O Profile
List of registered
functions for