RE856

OPERATION MANUAL

AUS

  

1300 734 253     NZ  0800 734 253

18

MAINTENANCE

Cleaning

Repairs or servicing are not covered in this operation manual and should only be performed by qualified personnel. Please 

return the meter to VALEN if this is the case. 

Periodically wipe the case with a dry cloth. Do not use abrasives or solvents on this instrument. 

Battery Check and Replacement

If the battery power is not sufficient, the         symbol will be shown on display. Replacement of six new 1.5V alkaline AA 

batteries is required. 

Prevention of Battery Fluid Leakage

When the battery power is low, replace the new batteries to avoid further battery fluid leakage possibility. 

When the meter will not be in use for an extended period of time, please remove the batteries out of the meter to prevent 

the possibility of battery fluid leakage damage. 

SOFTWARE

Hardware Requirements and Setup

PC Hardware Requirements

 

HDD, CD Rom, 486PC or above, with available COM port/USB port

 

EGA or higher

 

4M bytes or more memory size

PC Hardware Setup

1. 

Switch off all power related to the PC. 

2. 

Connect the USB cable to an available port. 

3. 

Switch on all related power.

4. 

Connect the optical plug end of the supplied cable to the meter. 

Software Requirements and Setup

1. 

Start up Windows operating system. 

2. 

Close all other applications.

3. 

Insert the disk into the CD drive.  

(if autorun does not start, open the CD drive then run ‘Install\setup’)

4. 

Follow the onscreen instructions: 

a.

b.

Содержание RE856

Страница 1: ...AUSTRALIA 1300 734 253 sales valen com au www valen com au NEW ZEALAND 0800 734 253 sales valen co nz www valen co nz OPERATION MANUAL RE856 BATTERY TESTER...

Страница 2: ...ry increasing growth the Lake Cargelligo Head Office moved into a brand new purpose built facility in 2012 In 2015 Regal Electro successfully completed its rst ENLiFEN Energy Storage Optimiser ESO pro...

Страница 3: ...done Upbeat Positive Attitude If our employees have a positive attitude and constantly strive to give your best effort eventually we will overcome our immediate problems and nd you are ready for grea...

Страница 4: ...nals 6 Screen Display 7 SPECIFICATIONS 8 General Specifications 8 Electrical Specifications 9 OPERATION 10 Preparation 10 Operation 10 Operation 11 Zero adjust Function 11 Pin type Test Lead Zero Adju...

Страница 5: ...RE856 OPERATION MANUAL 5 AUS 1300 734 253 NZ 0800 734 253 NAMES FUNCTIONS OF PARTS 1 2 3 6 9 4 5 7 8 10 17 11 13 14 12 15 16...

Страница 6: ...emory and auto data logging interval time setting mode press this key again to exit 7 key To turn the comparator function on and off Hold this key for 2 seconds to set the comparator setting mode pres...

Страница 7: ...omparator voltage low limit setting Measured battery charge capacity Measured battery discharge capacity Measured battery total capacity The calculated remaining capacity of the battery Shown when the...

Страница 8: ...isplay of or results and beeper for warning and fail results Low In High Low High Voltage Resistance Manual and auto data memory 999 sets can be read by meter and downloaded by PC Auto data logging Mi...

Страница 9: ...easurement Measuring current frequency 1kHz 30Hz Range Resolution Accuracy 6V 1mV 0 1 readings 6 digits 60V 10mV Voltage measurement Maximum input voltage 60VDC maximum no AC voltage input DO NOT EXCE...

Страница 10: ...a high voltage battery before continuing to measure a low voltage battery first short the measurement leads together This will discharge the DC elimination capacitor which is connected across the lead...

Страница 11: ...compared with the measurement range Zero adjust Function The zero adjustment function is to zero the range of resistance The reading during zero adjustments would be taken as zero and will be used to...

Страница 12: ...or adjustment The zero adjustment s valid for the currently selected range only as long as the power remains on Powering on the meter would reset all zero adjustment values Clip type Test Lead Zero Ad...

Страница 13: ...Connect the yellow miniature plug of the DCA current adaptor to the meter DCA CLAMP ADAPTOR jack 2 USE DCA CURRENT ADAPTOR Press the key of the DCA Current Adaptor to turn on the adaptor the POWER LE...

Страница 14: ...be The unit then displays with corresponding symbol and sounds a beeper with the WARNING and FAIL cases Comparator Settings 1 Rotate the resistance range switch to any range 2 Press and hold down the...

Страница 15: ...3 Press and keys to select the desired comparator number 01 99 The selected comparator number remains in memory even when the power is turned off 4 Press the key again to stop the comparator function...

Страница 16: ...y charge discharge remained capacity is Data Memory Function Manual and Auto Data Memory Function 999 sets To clear the Memorised Data When the memory is full the memory number 999 will appear on the...

Страница 17: ...splay will show NO XXX 2 Press the and keys to scroll through the memorised readings 3 Press key again to stop viewing the memorised readings 4 The memorised data can be read by transferring to PC Aut...

Страница 18: ...her battery fluid leakage possibility When the meter will not be in use for an extended period of time please remove the batteries out of the meter to prevent the possibility of battery fluid leakage...

Страница 19: ...User Account Control windows opens asking Do you want to allow the following program from an unknown publisher to make changes to this computer click Yes d e Online Operation 1 Click Run BatCapTester...

Страница 20: ...n A dialogue box will open input the file name select a file and then click the button Download Data Download Data from Hard Disk Click the button seventh from the left on the main screen Download Dat...

Страница 21: ...crosoft Excel and locate the saved file in Excel format for example test xls The Text Import Wizard then appears Follow the steps from 1 to 3 to complete Data Convert Excel Open a saved data file in t...

Страница 22: ...mpling Time PC Sampling Time Meter sampling rate is the rate at which the meter stores readings Click the button fifth from the left on the main menu Meter Sampling Rate Click the sixth from left on t...

Страница 23: ...om the right on the main menu Click to set the meter Set Comparator To erase the EEPROM click the button second from the right on the main menu Click to confirm Erase EEPROM To delete the SD card memo...

Отзывы: