28
FP7CE Antoinette - Installation and Operation Manual
WARNING: THE FIREPLACE MUST NOT BE IN CONTACT WITH ANY INSULATION OR LOOSE FILLING
MATERIAL. FOR THIS PURPOSE, COVER THE INSULATION WITH DRYWALL PANELS OR ANY
OTHER FINISHING MATERIAL INSIDE THE CHASE AROUND THE FIREPLACE.
Wall finish behind the fireplace’s
faceplate installation
CLEARANCES
A
227 mm
B*
293 mm
C*
86 mm
D*
2133 mm
MEASUREMENTS
E*
1321 mm
F*
686 mm
*When drywall panels or any other finishing material inside the chase around the fireplace is to be used,
add its thickness to the measurement. Clearances shown are for factory-built metal chimney with 2-inches
insulation or similar insulated flue system.