39
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019
USA
P. 540-563-2000
F. 540-362-9800
www.valcom.com
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019
USA
P. 540-563-2000
F. 540-362-9800
www.valcom.com
The numbers shown on the left are examples. Going down the list and entering every one of
the examples exactly as shown will cause the master clock to malfunction or use incorrect data.
Program your clock setting based off of the instructions in the description on the right.
Setting 21 - Once a Day Pulse - Clock #1 Circuit - Set Hour
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 23. For example, a value of 13 is the same as 1:00PM.
Set to 0 by default
.
Setting 22 - Once a Day Pulse - Clock #1 Circuit - Set Minutes
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 59.
Set to 0 by default
.
Setting 23 - Once a Day Pulse - Clock #1 Circuit - Set Seconds
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 59.
Set to 0 by default
.
Setting 24 - Once a Day Pulse - Clock #1 Circuit - Set Pulse Duration
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 99. For example, a value of 98 will set a pulse
duration of 1 minute and 38 seconds.
Set to 3 by default
.
Setting 25 - Programming the Clock #2 Circuit
(Output)
Press the bottom button to scroll from 1 to 9. These numbers correspond to the
different protocols listed under Setting 20.
Set to 8 by default
.
Setting 26 - Once a Day Pulse - Clock #2 Circuit - Set Hour
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 23. For example, a value of 13 is the same as 1:00PM.
Set to 0 by default
.
Setting 27 - Once a Day Pulse - Clock #2 Circuit - Set Minutes
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 59.
Set to 0 by default
.
Setting 28 - Once a Day Pulse - Clock #2 Circuit - Set Seconds
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 59.
Set to 0 by default
.
Setting 29 - Once a Day Pulse - Clock #2 Circuit - Set Pulse Duration
This setting only appears if “8” was selected under Setting 20. Press the bottom
button to scroll from 00 to 99. For example, a value of 98 will set a pulse
duration of 1 minute and 38 seconds.
Set to 3 by default
.
Manual Controls
21--14
22--00
23--30
24--05
25-- 1
26--14
27--00
28--30
29--05