947036
4
TECHNICAL SUPPORT
When trouble is reported, verify that power is being
supplied to the unit and that there are no broken
connections. Check input power for correct polarity.
Assistance in troubleshooting is available from the
factory. When calling, you should have a VOM,
several clip leads and be calling from the site. Call
(540) 563-2000 and press 1 for Technical Support
or visit our website at www.valcom.com.
The V-CCU is not field repairable. Valcom, Inc.
maintains repair facilities in Roanoke, VA. Should
repairs be necessary, attach a tag to the unit clearly
stating your company name, address, phone
number, contact person and the nature of the
problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, Virginia 24019-5056
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from
the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty
period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus
parts and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5.
all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any anticipated
profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters:
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019-5056
Phone: (540) 563-2000
FAX: (540) 362-9800
Connect to V-C6124P
power supply using the
cable supplied in the
V-VCU package.
Data error LEDs are
normally off and
illuminate to indicate
the absence of input
data.
Option switches
are used to set the
frequency of data
transmission and
slave mode (see
chart 1)
3 clock outputs are
provided. Each output
can be connected to
up to 40 Valcom
Analog clocks, 12
Valcom 2.5” Digital
Clocks or 10 Valcom
4.0” Digital Clocks.
2 Amps are available
per output.
Data output LEDs
flicker each time data
is sent to the clocks.
Data in may be provided
from a V-DCPI Digital
Clock Protocol Interface, a
V-
D11025 2.5” Digital
Clock, a V-
D11040 4.0”
Digital Clock, a V-WMC
Wireless Master Clock
Transceiver, a V-GPS
GPS Receiver, a VECRA
Remote Card Adapter or a
clock output from another
V-CCU.
Visit www.valcomclocks.com for
clock connection diagrams and
CAD drawings.