V-CCU Mounting 

 

Plug the 24V wiring harness from the 
V-C6124P into the POWER IN connector of the 
V-CCU. 

 

Position the V-CCU directly below the  
V-C6124P.  Using the 24V wiring harness as a                                             
measure, align the V-CCU under the  
V-C6124P where the wiring harness is not 
stressed (See Figure 1). 

 

Using the unit as a template, mark the mounting 
hole locations on the mounting surface. 

 

Disconnect the wiring harness and mount the 
V-CCU to the wall. 

 
 
V-CCU Wiring 

 

Re-attach the 24V harness to the V-CCU. 
Dipswitch functionality requires that 24V be 
applied to all three 24V inputs.  

 

Connect the data out from a V-DCPI Digital 
Clock Protocol Interface, a V-

D11025 2.5” 

Digital Clock, a V-

D11040 4.0” Digital Clock, a 

V-WMC Wireless Master Clock Transceiver, a 
V-GPS GPS Receiver, a VERCA Remote Card 
Adapter or a clock output from another V-CCU 
to the “DATA IN” RJ-11 on the V-CCU.  Dress 
the wires behind the V-CCU as shown. 

NOTE:  

The V-CCU data input is not polarity 
sensitive

.  See FIGURE 2 for data 

connection detail. 

 

Dress the peripheral clocks home run wiring 
behind the V-CCU as shown (See Figure 1).

 

 

If your system will use more than one         
V-CCU, you must connect a common 
ground.  Simply connect one of the negative 
(-) outputs of each V-

CCU’s V-C6124P power 

supply together. 

 

Connect the home runs to the plug-in terminal 
strip provided. 

 

NOTE:  

Maximum of 2 Amps per Clock output. 

 

 

Plug the terminal strip into the Clock Output 
connector on the V-CCU. 

 

DO NOT APPLY POWER YET!

  The clock 

correction interval must be set prior to 
energizing the unit.  See Setup and 
Programming. 

             
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
           