Setup and Programming 

 

If using a V-GPS, a V-WMC or a V-D110XX 
Digital Clock as a data source, set the clock 
data correction 

interval on these units for “one 

second”. (Refer to the individual product 
manuals for details).  If using a V-DCPI or a 
VERCA as a data source, program the Valcom 
intercom to provide “digital out” and “24-Hour 
Enhanced”. 

 

Using the V-CCU dipswitches set the desired 
clock correction intervals using chart 1 below. 

 
 

Switch 

Switch 

Switch 

Switch 

1 SEC 

Down 

Up 

Up 

Up 

1 MIN 

Up 

Down 

Up 

Up 

10 MIN 

Up 

Up 

Down 

Up 

1 HR 

Up 

Up 

Up 

Down 

SLAVE 
MODE 

Down 

Down 

Down 

Down 

CHART 1: CORRECTION INTERVAL 

 

Spare pairs in multi conductor talkback speaker 
cables, as are often used for classrooms, may be 
used to distribute Valcom 2-wire digital clock 
correction signals.  Do Not use spare pairs in multi 
conductor one-way speaker cables to distribute 
clock correction signals 

– use dedicated clock 

cabling for one-way speaker areas.  
 
Dedicated clock cabling should also be used for 
digital display clocks that will be utilized to display 
the word “Fire” or “Bell”. 
 
During initial setup, the V-CCU dipswitches should 
be set to send data every second. 
 
Once initial setup is complete: 
 
If the V-CCU is connected to the clocks through 
dedicated cabling then the V-CCU dipswitches 
should be set to send data every ten minutes. 
 
If the V-CCU is used with a Class Connection 
VECPU-5, a VECPU rev 4.02 or higher or a V-
CPU4 rev 3.16 or higher, then the V-CCU 
dipswitches should be set to send data every ten 
minutes. 
 
If the V-CCU is used with digital display clocks that 
will be utilized to display the word “Fire” or “Bell”, 
then the V-CCU dipswitches should be set to send 
data every second. 
 
 
 
 

Otherwise, when initial setup is complete, change 
the V-CCU dipswitches to send data every hour. 
 
 

 
 

              
 
 
     
FIGURE 2:  DATA IN RJ-11 DETAIL 
 

Data is connected via the two center pins of the 
“DATA IN” RJ-11 connector.   Electrical shorting of 
any RJ-11 pins or terminations may result in unit 
failure.  

 

The 24V and GND connections are provided as a 
power source for the V-DCPI Digital Protocol 
Interface. 

 

Initialization Self Test 

Plug the V-C6124P into the AC receptacle.  After 
approximately two seconds, the three RED LEDs 
on the V-CCU should blink twice and then 
extinguish when the unit begins to receive data 
from the master clock.  This indicates that the unit is 
energized and operating properly. 
 

NOTE:  

During the power up self-test, it is normal 

             for the LEDs to blink out of sequence.  
 
After the initialization self test, the three GREEN 
LEDs should illuminate, indicating that 24V is being 
supplied to the clocks.  The GREEN LEDs will 
flicker periodically following data transmission to the 
clocks. 

 

OPERATION 

The V-CCU provides 24VDC power and correction 
data over a single pair of wires to Valcom clocks.  
The unit can be programmed to send the correction 
data out once every second, every minute, every 
ten minutes or every hour.  RED LEDs indicate that 
the unit is not receiving input data.  GREEN LEDs 
indicate that 24VDC is being supplied to the clocks.  
The GREEN LEDs will flicker when correction data 
is supplied to its respective output. 
 

Master/Slave Mode 

Systems requiring multiple V-CCUs may be wired in 
a master/slave configuration with one of the clock 
outputs connected to the “Data In” of one or more 
slaves.  Slave units must be mounted within 500 
feet of the master and must have all of their 
dipswitches set to the “down” position (slave mode). 
 

Pin 1 24V out to V-DCPI 
Pin 2 GND out to V-DCPI 
Pin 3 Data 
Pin 4 Data 
Pin 5 GND out to DCPI 
Pin 6 24V out to V-DCPI 