manualshive.com logo in svg
background image

 

 

 

 

 

 

 

Issue 6 

 

1                                                                 947036 

 

V-VCU 

CLOCK CONTROLLER PACKAGE

 
GENERAL 

The Valcom Clock Controller provides 24VDC 
power as well as automatic synchronization and 
correction to Valcom clocks when used with a 
V-DCPI Digital Clock Protocol Interface, a 
V-D11

025 2.5” Digital Clock, a V-D11040 4.0” 

Digital Clock, a V-WMC Wireless Master Clock 
Transceiver, a V-GPS GPS Receiver, a VERCA 
Remote Card Adapter or a clock output from 
another V-CCU. 
 

PACKAGE INCLUDES 

 

1 Valcom V-CCU Clock Controller 

 

1 Valcom 24V Power Supply V-C6124P 

 

1 24V Wiring Harness 

 

1 6-Pin Silver-Satin Cord 

 

1 6-Pin RJ-11 Wiring Block 

 

SPECIFICATIONS 

Outputs 

Three individual 2 Amp, 24VDC outputs are 
provided to power up to 120 Valcom Analog clocks, 
36 Valcom 2.5” Digital Clocks or 30 Valcom 4.0” 
Digital Clocks.  
 

Inputs 

 

Correction data 

 

24VDC input power 

 

Features 

 

Supports two wire clock operation 

 

Individual current limited 2 Amp outputs  

 

User selectable correction intervals 

 

Data error LED indicators 

 

Power/Data output LED indicators 

 

Dimensions/Weight 

 

2.63”H x 12.36”W x 7.75”D 

      (6.7cm H x 31.4cm W x 19.7cm D) 

 

7lbs. ( 3.2 kg ) (with power supply) 

 

Power Requirements 

The V-CCU requires 24VDC 2 Amps per output 
(V-C6124P included). 
 

 
 

 

 

Environmental 

Operating Temperature:                     -0 to +40° C 
Humidity:                          0-95% non-precipitating 
 

Wiring Requirements 

 

24AWG UTP, CAT 3/5/5E/6 

 

INSTALLATION 

Precautions 

Failure to observe the following precautions could 
result in damage to the V-CCU. 

     Make all connections to the V-CCU and 

associated equipment with the input power 
removed.  Check and verify all connections 
before applying power. 

 
V-C6124P Mounting Instructions 

 

Locate an area on the wall capable of 
supporting the weight of the power supply 
(approximately 5 pounds) within six feet of an 
AC receptacle. 

 

Using the mounting bracket as a template, mark 
the two slotted holes on the mounting surface. 

 

Using the two #8 screws enclosed, mount the 
bracket to the mounting surface as shown 

      (See Figure 1). 

 

Slide the V-C6124P onto the mounting bracket. 

 

V-C6124P Wiring Instruction

 

 

Plug the AC cord into the V-C6124P only. 

 

      

(Do NOT plug into the AC outlet)

 

 

Plug the wiring harness packaged with the 
V-CCU into the output connector of the 
V-C6124P (See Figure 1). 

 

 

 

Отзывы: