background image

 

947923 

BK/BL

BL/BK

Diode 1N4003 or eq.

(Portion of
Connecting
Block)

DC Power Supply
depends on relay
requirements

Relay Coil

FIGURE 7

CONNECTIONS OF V-9923B FOR

OPERATING A DC SLAVE RELAY

THREE DIGIT
OPERATION

TWO DIGIT
OPERATION

NO CODE
VERIFICATION

CODE
VERIFICATION

MUST BE IN THE ON POSITION

SOLID
LAMP

FLASHING
LAMP

SW

OFF

ON

1

2

3

4

2 DIGIT CODES:  11-19, 21-29, ., 91-99

3 DIGIT CODES:  111-119, 121-129,
                     ...., 991-999

OFF   ON

FIGURE 8

OPTION SWITCH SETTINGS

LINE

SUPERVISION

BATTERY
   FEED

RING

DETECTOR

K2

TONE OR ROTARY
PULSE DECODING

OSC. AND
AMPLIFIER

LOGIC AND
  MEMORY

K1

TT
40
RT
15

OUT

36
IN

11

TONE
OUTPUT

SW ITCHED
RELAY
OUTPUT

K1

K3

TO ANALOG

STATION OF

PBX (ANSW ER)

TO
29

RO

4

T
26

R
1

K2

K2

TO PBX TRUNK OR
SPARE LINE BUTTON
ON TELEPHONE
(ACCESS)

K4

LS

 INHIBIT
CIRCUIT

CONTROL
 CIRCUIT

EP1

2

L
27

INH
3

LAMP SUPPLY

LAMP ON LINE BUT.

"A" LEAD OF LINE BUT.

47

EP2

22

TO NEXT
V-9923B

K3

VOLT
 REG.

A GND.

A BATT.

B GND.

B BATT.

FIGURE 9

V-9923B SIMPLIFIED SCHEMATIC

K1

OUT

IN

 

 

Содержание V-9923B

Страница 1: ...t is installed SPECIFICATIONS The V 9923B is capable of providing code signaling for paging purposes it provides for meet me answer of code call and provides talk circuit and signaling tone Features T...

Страница 2: ...stem Figure 2 is a simplified block diagram showing the code call unit and its connections NOTE The code call unit is designed so that it will complete a code call sequence before resetting and return...

Страница 3: ...connect the V 9923B to a PABX are shown in Figure 4 The V 9923B requires a loop start trunk port from the PABX for access If more than one link of code call is being provided the second V 9923B would...

Страница 4: ...ED TO PREVENT TWO CODES BEING BROADCAST SIMULTANEOUSLY The calling party then dials in a two or three digit number depending upon the position of dipswitch 1 on the code call unit After the last digit...

Страница 5: ...he warranty period provided that 1 inspection by Valcom Inc indicates the validity of the claim 2 the defect is not the result of damage misuse or negligence after the original shipment 3 the product...

Страница 6: ...K G G BK BK BR BR BK BK S S BK Y BL BL Y Y O O Y Y G G Y Y BR BR Y Y S S Y V BL 1 2 3 4 5 BL V V O O V V G G V V BR BR V V S S V 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30...

Страница 7: ...KEY STRIP A1 H S PART OF KEY TELEPHONE INSTRUMENT FIGURE 5 CONNECTION OF V 9923B TO KEY SYSTEM V 9923B LS IN O W 4 BL BK 22 AG AB V BR 47 BR V 48 V S 49 BG V 9923B S V 50 BB 10 Vac LG AG GROUND AB 24...

Страница 8: ...T CODES 111 119 121 129 991 999 OFF ON FIGURE 8 OPTION SWITCH SETTINGS LINE SUPERVISION BATTERY FEED RING DETECTOR K2 TONE OR ROTARY PULSE DECODING OSC AND AMPLIFIER LOGIC AND MEMORY K1 TT 40 RT 15 OU...

Отзывы: