background image

 

947980

 

Indicators 

(Figure 1)

 

 

Power “ON”  

 

Individual message play 

 

Visual system fault 

 

Audible system fault with silence button  

 

Inputs 

(Figure 2)

 

 

Eight remote message activation inputs via 
single pole pushbutton switches. 

 

RS-232 provided for message uploads and 
downloads. 

 

Handheld microphone for “live” announcements 

 

Outputs 

(Figure 2) 

 

Audio output 

 

Page/Message active contact 

 

External contact closure activates on system 
fault. 

 

System Operation 

The Push-to-Talk microphone is used for live pages. 
The microphone has priority over message playback 
paging.  Pressing the Push-to-Talk switch on the 
microphone will activate the audio output and 
override (and CANCEL) any message playback in 
process. 

 

A group of eight (8) front panel buttons with 
associated LED’s are used to activate stored 
messages.  When a message is activated, the LED 
will indicate the status.  If the message is playing, 
the LED will illuminate.  

Messages are not 

chainable

.  A message must be finished before an 

additional message may be activated.  If a message 
button is pressed while a message is playing the 
original message will cancel. 

 

A “MESSAGE CANCEL” button is available to 
cancel any message playing. 

 

Using the program tool, all messages can be 
programmed for the following play scenarios: 

 

1 play per button activation 
2 plays per button activation 
3 plays per button activation 
Continuous plays per activation (cancelled via 
“MESSAGE CANCEL” button) 

 

Programming Voice Messages 

Eight (8) preprogrammed messages are provided in 
the V-9908. (See Table 1, for script of 
preprogrammed messages). 

 

A serial port (RS-232) is provided to upload and 
download voice messages.  The

 

program tool

  

provides all editing and message

 

processing (AGC, 

response shaping, wave file conversions, etc.).

The final format is standard 8 bit uLaw at 8kHz 
compressed format. 

 

Although it is possible to upload and download 
during system operation, it is recommended to 
perform this function when the system is not in use.  
This insures that messages will not be corrupted 
during a download or upload.   

After message write 

remove battery and DC power momentarily. 

Total voice message storage is 8 minutes and there 
are no other restrictions on lengths of individual 
messages.  It is possible to record tones, signals, 
etc. that will operate in the voice band range.   For 
additional programming information refer to the 
Message Control Panel Program Tool Help Menu. 

 

System Fault Monitoring 

The main audio channel has an inaudible tone 
present whenever a page or message is not active.  
This tone will verify the integrity of the audio channel 
from the microphone to the audio output.  A Valcom 
V-1096 Audio Interface (included) is required when 
the speaker runs are non-supervised. 
 

 

Proper operation of the voice memory flash device is 
monitored by continuous reading a fixed segment of 
the memory.  This insures the flash memory integrity 
as well as the circuitry that attaches it to the DSP 
controller.  It will detect defective components and 
interconnection faults as well as actual memory 
failure. 

 

In the event of a system or power failure, the 
“System Fault LED”

 

will illuminate and an

 

audible 

alarm will sound.  The Audible alarm may be 
silenced by pressing the “Cancel Audible” button, 
however the “System Fault” LED will remain lit until 
the fault has been corrected.  A 9 Volt battery 
located on the back of the Page Panel provides the 
necessary power to operate the fault circuits in the 
event of a power failure.  The 9 Volt battery is 
monitored and a system fault will occur when the 
battery voltage drops.  A contact closure is available 
to signal a remote monitoring panel when a system 
fault occurs. 

 

Full System Supervision

 using Valcom One-Way 

Supervised Self-Amplified Speakers and Horns with 
the Page Panel includes monitoring of the audio and 
power pairs to the speakers for shorts, opens and 
grounds.  A fault detected on these lines will cause 
the “System Fault” LED to illuminate.  A Valcom  
V-9999 End of Line device (not included) is required 
for speaker line termination. 

 

Installation 

Refer to the figure on the following pages for wiring 
connections.  All connections should be made to the 
Message Panel and double-checked prior to 
connecting DC power. 

Отзывы: