Mounting

 

The V-2001A was designed for wall or table 
mounting.  Secure unit to wall studs or a suitable 
brace away from heat sources or strong 
magnetic fields (Motors, fans, power supplies, 
etc.) with the control and terminal strip 
accessible.  Four wood screws are included for 
mounting. 

 
Power Connections

 

NOTE:  This equipment must be installed 
near an AC power outlet due to the power 
cord being used as a disconnect device. 

 

  The V-2001A is provided with a NEMA 5-15 

cord set for North American use. 

  Connect cord set to unit via IEC 320 female 

connector located on one end of cord set to 
IEC 320 male appliance coupler located on 
the V-2001A. 

 

  For 115VAC use, verify fuse rating of 1 Amp 

and voltage selector switch displays 115V. 

  For 230VAC use, verify fuse rating of 0.5 

Amp and voltage selector switch displays 
230V. 

 

After all required connections 
have been made, plug the cord 
set into appropriate AC wall 
outlet. 

 

CONNECTIONS 

Refer to Figure 1. 
 

Electronic Key or PABX Access

 

When using the V-2001A with an electronic key 
system, C. O. line position or PABX trunk port, 
the battery feed switch (SW1) must be ON. 

 

Pre-Page Alert Tone Option

 

The Pre-Page Alert Tone may be used when 
accessing the unit from an electronic key 
system, C. O. Line position, PABX Trunk Port or 
a Page Port with a contact closure.  Page Ports 
must provide a contact closure output.  To 
enable the pre-page alert tone feature, place a 
jumper on the yellow and black leads (outer pair 
of RJ-11) of J3.  (See Figure 1). 

NOTE: The pre-page alert tone operates on 
the primary paging input only. 

 
 
 

 

Operation

:  Press line key (Electronic key 

system) or dial trunk access code (PABX) to 
connect to the paging speakers.  Make 
announcement.  The V-2001A automatically 
disconnects from page. 

 

Page Port Access

 

When accessing the V-2001A from a telephone 
system page port, the battery feed switch (SW1) 
must be OFF. 

 

Operation

:  

Follow the telephone system 

manufacturer's instructions for access to 
external paging.   Make announcement.  The 
V-2001A automatically disconnects from page

 

The V-2001A voice switching circuit is activated 
when the person making the page begins to 
speak. When the page is completed or the 
person stops speaking for more than two 
seconds, the paging circuit turns off.  Other 
functions of the unit remain the same. 

 
Background Music 

Background music may be connected to the 
V-2001A when using either access method.  
Background music mutes on the "page + music" 
outputs when a page is made. 
 
Connect the output of a low level music source 
to the screw terminals marked "Music" on the 
input terminal strip on the V-2001A.  Adjust 
music volume control on the V-2001A to the 
desired level. 
 

Night Ring and Single Tones

 

Night ringing (Electronic warble tone) over 
paging is activated by a common audible 
contact closure or 90VAC ring voltage. 
 
A single tone (Time clock) over paging is 
provided when the V-2001A is connected to a 
contact closure.  
 

Tone Options

 

SW4 enables or disables single and warble 
tones on all page outputs.  SW2 enables or 
disables single tones and warble tones on the 
page without music output only. 

 
 
 
 
 
 
 