User’s Guide ______________________________________________________________________
112 _________________________________________________________________ M211840EN-C
Examples (device address 0):
0R1!
0+323+331+351+0.0+0.4+3.0<cr><lf>
0R3!
0+0.15+20+0.0+0.0+0+0.0+0.0+0.0<cr><lf>
0R!
0+178+288+001+15.5+27.4+38.5+23.9+35.0+1002.1+0.00+0+
0.0+23.8<cr><lf>
Continuous Measurement with CRC
(aRC)
Command format:
aRCx!
The device can be configured so that all the parameters can be requested
instantly with the command aRC but a three-character CRC is added to
the response data strings before <cr><lf>.
Example (device address 0):
0RC3!
0+0.04+10+14.8+0.0+0+0.0INy
Содержание WXT536
Страница 1: ...USER S GUIDE Vaisala Weather Transmitter WXT530 Series M211840EN C...