![Vaisala WINDCAP WS425 Скачать руководство пользователя страница 79](http://html.mh-extra.com/html/vaisala/windcap-ws425/windcap-ws425_user-manual_849075079.webp)
Chapter 7 ____________________________________________________________ Technical Data
VAISALA _______________________________________________________________________ 79
CHAPTER 7
TECHNICAL DATA
This chapter gives the technical data on the product.
Specifications
Table 16
Technical Specifications
Wind Speed
Measurement range
serial
output
analog
output
0 ... 65 m/s (0 ... 144 mph, 0 ... 125 knots)
0 ... 56 m/s (0 ... 124 mph, 0 ... 107 knots)
Starting threshold
virtually zero
Delay distance
virtually zero
Resolution
0.1 m/s (0.1 mph, 0.1 knots, 0.1 km/h)
Accuracy (range 0 ... 65 m/s)
±
0.135 m/s (0.3 mph, 0.26 knots) or 3 % of reading,
whichever is greater
Wind Direction
Measurement range
0 ... 360°
Starting threshold
virtually zero
Delay distance
virtually zero
Resolution 1°
Accuracy (wind speed over 1 m/s)
±
2°
Outputs
Digital outputs
type
RS-232, RS422 or RS485, four different message
formats
bit rate
adjustable from 1200 to 19200 bit/s
available averages
RS-232: 1 to 9 seconds
SDI12- Standard Data Interface
type
3 wires for ground, signal and supply
bit rate
fixed 1200 bit/s
available averages
1 to 3600 seconds
Analog outputs
wind
speed
frequency
5
Hz/mph
voltage
8.0
mV/mph
output impedance
10 kohm
wind
direction
simulated potentiometer
0 ...V
ref
represents 0 ... 359°
reference voltage
1.0 ... 4.0 V
output impedance
24 kohm