Missing Readings
If data is missing due to a measurement problem, the NMEA messages
will only show the commas (,) between the data fields. Thus, NMEA is a
variable-length data message.
NMEA Extended Message
Vaisala extension to the standard MWV wind message is defined as
follows:
$P<id>MWV,<dir>,<ref>,<spd>,<uni>,<sta>*<chk><cr><lf>
where
$P =
Fixed
text
<id>
=
Is the data ID; A … Z
MWV =
Fixed
text
<dir>
=
Wind angle, 0 to 359 degrees
<ref>
=
Reference; R = Relative, T = True
<spd> =
Wind
speed
<uni>
=
Wind speed units; K = kmph [km/h],
M = mps [m/s], N = kt
<sta>
=
Status; A = Data Valid, V = Invalid Data
* =
Fixed
text
<chk>
=
Checksum (8-bit XOR, excluding $ and *)
<cr>
=
Carriage return code, ASCII 0DH
<lf>
=
Line feed code, ASCII 0AH
NOTE
The sensor has a 20 ms timeout in receiving characters. Thus, polling
strings should be transmitted by a programmable device, not as a user
command via terminal sessions.