![Vaisala WINDCAP WS425 Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/vaisala/windcap-ws425/windcap-ws425_user-manual_849075056.webp)
USER'S GUIDE____________________________________________________________________
56 __________________________________________________________________ M210361EN-E
Send Identification Command (aI!)
This command is used to query sensors for their SDI-12 compatibility
level, model number, and firmware version number.
The following is an example of the command:
aI!
where
a
=
The sensor address.
I
=
The send identification command
!
=
Terminates the command.
The following is an example of the response:
allccccccccmmmmmmvvvxxx . . . xxx<CR><LF>
where
a
=
The sensor address.
ll
=
The SDI-12 version number, indicating
SDI-12 version compatibility; for example,
version 1.1 is encoded as 11.
cccccccc
=
An 8-character vendor identification Vaisala
_
mmmmmm =
6
characters
specifying the sensor model number
WS425.
vvv
=
3 characters specifying the firmware version
604.
For example,
xxx ... xx
=
An optional field, up to 13 characters, used for a
serial number or other specific sensor
information that is not relevant for operation of
the data recorder (not used).
<CR><LF>
=
Terminates the response.
Address Query Command (?!)
When a question mark (?) is used as the address character with the
acknowledge active command (
a!
), the sensor will respond as if it is
being addressed on the SDI-12 bus. For example, if a sensor detects
?!
, it
will respond with
a<CR><LF>
,
no matter what its address may be. This
will allow a user to determine the address of a sensor. The user should
understand that if more than one sensor is connected to the bus, they will
all respond, causing a bus contention.