background image

U

SER

'

G

UIDE

___________________________________________________________________________

U370EN-1.1___________________________________________________________________________4

PIN

SIGNAL

   1

not used

   2

TX

   3

RX

   4

not used

   5

ground for RS 232

   6

not used

   7

not used

   8

not used

   9

not used

RS485

The pin assignment of the RS485 serial interface connector of the
PTB220TS/CASE is as following:

PIN

SIGNAL

1

not used

2

RS485 HI

3

not used

4

not used

5

RS485 LO

6

not used

LED Indicators

There are four 

LED

 indicators in the back plate of the tilting frame. The

LED

 indicators inform the user of operating status of the barometer.

The green 

PWR

 led indicates that the PTB220 barometer is switched

ON.

The red 

BATT

 led indicates that the internal lead battery is being

recharged. When the battery is fully charged the led returns dark.

The yellow 

TX / RX

 leds indicate that there is activity in the serial line.

All manuals and user guides at all-guides.com

Содержание PTB220Case

Страница 1: ...PTB220TS CASE USER S GUIDE U370EN 1 1 JUNE 1999 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...y form or by any means electronic or mechanical including photocopying nor may its contents be communicated to a third party without prior written permission of the copyright holder The contents of in...

Страница 3: ...voltage 2 Tilting frame 3 Battery 3 RS232 3 RS485 4 LED Indicators 4 ASSEMBLING THE CASE AND AN EXISTING BAROMETER 5 TECHNICAL DATA 7 Electronics 7 Electromagnetic compatibility 7 Battery 7 Housing 7...

Страница 4: ...s A accuracy local display RS232 485 serial interface This guide gives the basic operating instructions of the PTB220TS It does not however replace the operating manual of the PTB220 series digital ba...

Страница 5: ...connector is detached For measurement the connector MUST be on place Operating voltage DC voltage of 10 25 VDC is required to operate the barometer A power cord with a suitable plug in connector is s...

Страница 6: ...wards NOTE The pressure connector has to be removed before closing the wooden carrying case Battery The battery gives a twelve hour service period The period is even longer if the back light is not us...

Страница 7: ...is as following PIN SIGNAL 1 not used 2 RS485 HI 3 not used 4 not used 5 RS485 LO 6 not used LED Indicators There are four LED indicators in the back plate of the tilting frame The LED indicators info...

Страница 8: ...the barometer is installed into the case 1 Remove the wooden tilting frame from the case 2 Unscrew the base plate 3 Attach the PTB220 onto the base with four M6x16 screws 4 Thread the flat cable betw...

Страница 9: ...ing wire end to left hand side 9 Attach the spacers 2 pcs M3x12 Fix the support bar of the pressure port to the spacers 10 Attach the M3x18 spacers 4 pcs 11 Connect the flat cable and the battery cond...

Страница 10: ...lex Connectors 9 pin female sub D connector 6 pin 5 mm screw terminal bus Electromagnetic compatibility PTB220TS CASE with the PTB220 barometer is fully compatible according to standards EN50081 1 EN...

Отзывы: