Vaisala GroundCast DRS611 Скачать руководство пользователя страница 6

2. Activating device

Go to the installation location to perform the device activation.

1.

 Open the mobile

application and select

Connect to device

.

Hold the phone close to the
NFC symbol and wait until
the device is shown on the

application.

2.

 Select 

Start activation

.

Follow the onscreen
instructions.

3.

 Complete the activation.

The device is sending
measurements to the
cloud.
When the device has been
active for 60 minutes, it is
no longer possible to
access the device with a
phone.

3. Drilling hole for device

• Depth 360 mm (14.2 in)

• Diameter 60 mm (2.4 in)

1.

 Use water when drilling

asphalt or concrete.
Remove the asphalt block
from the drill bit.

2.

 Do not use water when

drilling gravel.
Drill approx. 50 ... 100 mm
(2 ... 4 in) at a time. Clean
the drill bit in between to
avoid gravel from sticking

inside.

3.

 Verify the correct depth

with the dummy block. If
the hole is too deep, add
filler sand.
If there is water in the hole,
use a cloth to dry it.

6

M212671EN-C

Содержание GroundCast DRS611

Страница 1: ...M212671EN C Setup and Removal Guide DRS611 Vaisala GroundCast...

Страница 2: ...en time and hereby disclaims any and all responsibilities related thereto This document does not create any legally binding obligations for Vaisala towards customers or end users All legally binding o...

Страница 3: ...surface type must be asphalt or concrete Do not install the device on gravel roads Do not install GroundCast on bridges To make sure that the sealant dries properly the air temperature must be above...

Страница 4: ...from around the sensor Sealant pack 2 pcs Installation of 1 device requires 1 2 sealant packs Installation kit 1 customer Adjustment block Device holder Dummy block Sealant applicator SEALANT Other n...

Страница 5: ...ce Hold the phone close to the NFC symbol and wait until the device is shown on the application Do not start activation of the device until you are at the installation location 4 Check the signal stre...

Страница 6: ...When the device has been active for 60 minutes it is no longer possible to access the device with a phone 3 Drilling hole for device Depth 360 mm 14 2 in Diameter 60 mm 2 4 in 1 Use water when drilli...

Страница 7: ...ell mixed Note that in temperatures above 5 C 41 F the sealant dries in 5 minutes 3 Apply sealant to the top of the SIM card cover filling the black slot Leave the clear part visible SEALANT 5 min 4 A...

Страница 8: ...eve and the overflown sealant 2 The device surface must be 1 3 mm 0 04 0 12 in below the road surface If the device is on the road surface level or above the road surface use the adjustment tool to lo...

Страница 9: ...azardous waste regulations Needed equipment GroundCast removal tool Power drill and 6 mm drill bit Screwdriver 13 mm wrench 1 Removing device 1 Drill a hole to the top of the device with a 6 mm drill...

Страница 10: ...nfrastructure vary in each country these instructions only indicate the different components to be separated and common ways to handle them Always follow local requirements when disposing of the produ...

Страница 11: ...yclers WARNING The sensor contains a battery which poses a fire explosion and severe burn hazard Do not crush disassemble heat above 100 C 212 F or incinerate WARNING Recycle the device in accordance...

Страница 12: ...stallation work Consider also the effects of local weather conditions WARNING When performing installation and maintenance procedures at the roadside follow local and state legislation and regulations...

Отзывы: