USER'S GUIDE ____________________________________________________________________
92 ___________________________________________________________________ M211187EN-C
Simulated Test Messages
Visibility Sensor FS11 can be set to a simulation mode, which includes
transmitting fixed or user defined visibility and status information. This
function is intended for system testing purposes. The normal visibility
detection mode takes effect after a reset. The simulation mode can also
be stopped with the advanced level command
SIMULATE OFF
.
The user can either choose a fixed test message or define an entire
message content. The fixed simulation message is selected with the
advanced level command
SIMULATE TEST_MESSAGE
.
There is a predefined fixed test message for each message type. If a fixed
test message is selected, one of the messages in the following section is
transmitted depending on the message type selection. The data values in
the messages are as shown in the following section. The frames of the
messages are not fixed but depend on the current configuration.
When changing the predefined fixed test message type, first turn the
simulation off by giving the advanced level command
SIMULATE OFF
and then change the message type (with command
SET MESSAGE
TYPE
number
). Turn the simulation on again by giving command
SIMULATE TEST_MESSAGE
.
Message 3 (Status message) has no simulation message.
Fixed Test Messages
Message 1
!
FS
∀
EXT 1.62 AL 0 ALS 00319 AL 0
#
66D9
∃−∗
Message 2
!
FS
∀
VIS 01850 AL 0 BL 01100 AL 0
#
FFAC
∃−∗
Message 4
!
FS
∀
VIS 01850 VUC 01800 VIS3M 01900 VIS10M 02000 AL 0 BL 01100 BUC
01050 AL 0
#
68F7
∃−∗
Message 5
!
FS
∀
VIS(01850(AL(0)))BL(01100(AL(0)))
#
663B
∃−∗
FD12 Message 2 Emulation Message
!
FD 1
∀
00 1850 2000 //// // /////
#−∗