![Vaisala FS11 Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/vaisala/fs11/fs11_user-manual_849045069.webp)
Chapter 4 _________________________________________________________________ Operation
VAISALA ________________________________________________________________________ 67
Command
Description
PORT.
SET MODULE MODEM V21 ORIGINATE
yes/no
(DMX501 only)
300 bps modem mode, ORIGINATE mode. Verification
yes/no asked only if the command is given through
DATA PORT.
SET MODULE MODEM V21 ANSWER_NC
yes/no
(DMX501 only)
300 bps modem mode, ANSWER mode and no carrier
on standby. The carrier is on only during message
sending. Verification yes/no asked only if the command
is given through DATA PORT.
SET MODULE MODEM V22 ANSWER
yes/no
(DMX501 only)
1200 bps modem mode, ANSWER mode. Verification
yes/no asked only if the command is given through
DATA PORT.
SET MODULE MODEM V22 ORIGINATE
yes/no
(DMX501 only)
1200 bps modem mode, ORIGINATE mode. Verification
yes/no asked only if the command is given through
DATA PORT.
SET MODULE MODEM V22BIS ANSWER
yes/no
(DMX501 only)
2400 bps modem mode, ANSWER mode. Verification
yes/no asked only if the command is given through
DATA PORT.
SET MODULE MODEM V22BIS
ORIGINATE
yes/no
(DMX501 only)
2400 bps modem mode, ORIGINATE mode. Verification
yes/no asked only if the command is given through
DATA PORT.
SET MAINTENANCE_PORT BAUD
number
Sets the Maintenance port serial line baud rate to
300...9600. Communication parameters: 8N1 (fixed).
SET PORT_TIMEOUT
number
Sets the command mode timeout to 0 ... 30, in minutes.
Zero disables the timeout, and the default is 10 min.
SET TERMINAL_LINES
number
Adjusts printouts used for terminal screen. Minimum 5
lines (default 24).
MEAS_SYNC
Resets the measurement sequence. The following data
message is measured starting from the moment all
average values are erased. Next message is
transmitted in (in2) seconds.
SYSTEM
Lists system information: type, ID, software version,
hardware modules, serial numbers.
NAME
Displays the device type, device name given by the
user, and ID.
VERSION
Lists the software version.
Table 10
FS11 Advanced Level Commands
Command
Description
CALIBRATE WINDOW_CLEAN
VISIBILITY_SENSOR
Sets the clean references for contamination control (and
backscatter control) in FS11.
CALIBRATE WINDOW_CLEAN
BL_SENSOR
Sets the clean references for contamination control (and
backscatter control) in Background Luminance Sensor.
CALIBRATE VISIBILITY
calibration_value
Sets the visibility calibration value, which should be
between 0 and 10.
CALIBRATE VISIBILITY OFFSET
Sets the offset value for the visibility sensor. Before this
command is given, the optical blockers must be put to
transmitter and receiver of the visibility sensor. The
optical blockers are part of the FSA11 calibration kit.
CALIBRATE FS11
Invokes a Guided Calibration Procedure for the visibility
sensor. This procedure includes clean reference setting
for the visibility sensor, the offset determination for the
visibility sensor and the visibility calibration.