Chapter 3 ________________________________________________________________ Installation
VAISALA ________________________________________________________________________ 37
9.
Connect the measurement unit cable plug to the connector at the
bottom of FSM102 (see Figure 14 below).
0201-068
Figure 14
Connecting Measurement Unit
The following numbers refer to Figure 14 above:
1 = Measurement unit end gasket
2 = Transmitter
3 = Surface temperature probe
4 = Receiver
10. Insert the measurement unit into the pole mast and lock it in the
correct orientation as discussed in section Location and Orientation
on page 20 with two 8-mm bolts (see Figure 14 above). The
transmitter and receiver heads can be identified by first locating the
surface temperature probe, which is closer to the transmitter.
11. Erect the mast.