U

SER

'

G

UIDE 

 

June

 

2008

 

|

 

M010036EN-D 

 

TECHNICAL SPECIFICATIONS 

Dewpoint Temperature 

Measurement range 

-80 ... +60 °C (-112 ... +140 °F)

DMT242A 

-80 ... +20 °C (-112 ... +68 °F)

DMT242B 

-60 ... +60 °C (-76 ... +140 °F)

DMT242X free 

scaling

 
When the dewpoint is below 0  C, the transmitter outputs 
frost point. 
 
Dewpoint accuracy with 
DRYCAP

®

 180M 

±2 ºC (±3.6 ºF)

(See figure below) 
 

 

Response time 63 % [90 %] at 20 °C gas temperature at 
flow rate > 1 l/min and 1 bar pressure: 
-60 

 -20 °C T

d

 (-76 

 -4 °F T

d

5 s [10 s]

-20 

 -60 °C T

d

 (-4 

 -76 °F T

d

45 s [10 min]

 
DRYCAP

®

 180S 

±2 ºC (±3.6 ºF)

(See figure below) 

 

Operating Environment 

Temperature 

0 ... +60 ºC (32 ... +140 ºF)

Higher temperature peaks 

Short term OK

Relative humidity 

0 ... 100 %RH

Pressure 

0 ... 20 bar

a

 (0 ... 290 psi

a

)

Sample flow rate 

no effect

 

 

Output 

Analog output 

4 ... 20 mA

Resolution for analog output 

±0.002 mA

Typical temperature dependence 

0.0008 mA/ºC

Serial line for service use 

RS-232 

 

General 

Sensor DRYCAP

®

180M

Operation voltage 

17 ... 35 VDC

 

20 ... 28 VAC

Power consumption 24 VDC 

max 220 mA

External load for current 
output 

max 500 

Optional connection cable 
with DMT242 connector 

2 m or 10 m

Connector for supply voltage 
and signal output 
Max wire size 

0.75 mm

2

Max wire diameter 

6.5 mm/PG7

Service cable for serial line 

DMT242RS

Probe material 

stainless steel 

(AISI 316L)

Sensor protection 

stainless steel sintered 

filter (HM47280)

 
Mechanical connection 

G1/2" ISO228-1 thread 

with bonded seal ring 

(U-seal)

Electronics housing 

plastic (ABS/PC)

Housing classification 

IP 65 (NEMA 4)

Storage temperature range 

-40 ... +70 ºC

 

(-40 ... +158 ºF)

 
Complies with EMC standard EN61326-1:1997 + 
Am1:1998 + Am2:2001; Industrial Environment. 

 

Figure 4 Dimensions in mm [inches]

 

 

 