USER'S GUIDE____________________________________________________________________
38 __________________________________________________________________ M211371EN-B
Show Firmware Version
VERS
<cr>
Example:
vers
DPT145 1.0.23
Show Serial Number
SNUM
<cr>
Example:
snum
Serial number : F4040007
Serial Line Output Commands
Start Measurement Output
Use the
R
command to start the continuous outputting of
measurement values as an ASCII text string to the serial line. The
format of the measurement message is set with the
FORM
command.
R
<cr>
Example (measurement message in default format):
r
Tdf= 12.5 'C Tdfatm= 13.6 'C H2O= 15561 ppm P= 0.947
bara Pnorm= 0.943 bara Rhoo= 1.1 kg/m3 T= 24.5 'C
Tdf= 12.5 'C Tdfatm= 13.6 'C H2O= 15563 ppm P= 0.947
bara Pnorm= 0.942 bara Rhoo= 1.1 kg/m3 T= 24.5 'C
Tdf= 12.5 'C Tdfatm= 13.5 'C H2O= 15555 ppm P= 0.948
bara Pnorm= 0.943 bara Rhoo= 1.1 kg/m3 T= 24.5 'C
...
Outputting the results continues in intervals issued with the command
INTV
. You can stop the output by pressing the
Esc
key, or with the
command
S
. Since the interface is half-duplex, you must enter the
commands when the transmitter is not outputting.