![Vaillant VRT 392 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/vaillant/vrt-392/vrt-392_operating-and-installation-manual_848965016.webp)
h
Note!
The time programmes for hot water or for a dhw
circulation pump are set in the same way as
described for heating circuit 1. For hot water
and the dhw circulation pump, it is not
necessary to programme comfort temperatures.
4.7.2 Programming
holiday
periods
If you are not at home for a longer period, you can set a
lower room temperature. This will save heating energy.
The VRT 392 makes sure that the heating system heats
the living rooms only to the set temperature.
You can, e.g. set a room temperature of 15 °C, if you are
on holiday from the 10th - 24th February. The living
rooms are only heated up to 15 °C during this period.
Holiday times can be set as follows:
⇒
Turn the left-hand dial until the screen 7 "Holiday
programming for the cpl. system" is reached.
> Set starting day
Holiday programming
7
Period:
for cpl. system
Room temp.:
10 . 02 . 06 - . .
10 °C
Fig. 4.14 Screen 7 (example)
⇒
Turn the right-hand dial until the cursor
is at the
start of the start date.
In the display area for explanation the text "Set starting
day" appears.
⇒
Click the right-hand dial.
The field is highlighted.
⇒
Turn the right-hand dial until the day of the
desired day of the starting date is displayed.
⇒
Click the right-hand dial.
The day is now saved and the value is no longer
highlighted.
⇒
Set the month and the year of the starting date in
the same way.
In the display area of the explanation the text
"Set starting month" or "Set starting year" appears.
⇒
Set the end date of the holiday period in the same
way.
Enter the room temperature as follows:
⇒
Turn the right-hand dial until the cursor
is located
in front of the input field for the room
target temperature.
In the display field for the explanation the text "Select
room temperature" appears.
⇒
Click the right-hand dial.
The field is highlighted.
⇒
Turn the right-hand dial until the desired value is
displayed (values from 5 °C to 30 °C in half degree
steps are possible).
⇒
Click the right-hand dial.
The desired room temperature is set. The value is
saved and no longer highlighted.
4.7.3 Heating
settings
Here you can enter the set-back temperature. The
heating is set to this temperature outside the specified
time windows.
> Select temperature
HC1
8
Set back temperature
Parameter
15 . 0 ° C
Fig. 4.15 Screen 8 (example)
In the display area for explanation the text "Select
temperature" appears.
⇒
Click the right-hand dial.
The field is highlighted.
⇒
Turn the right-hand dial until the desired value is
displayed (values from 5 °C to 30 °C in half degree
steps are possible).
⇒
Click the right-hand dial.
The desired set-back temperature is set. The value is
saved and no longer highlighted.