Operating Manual VRT 392
12
Changing the operating mode in the default display
Operating
mode
Meaning
Auto(matic)
The boiler is controlled according to the
programmed room temperature, time
programmes and other parameters
such as e.g. the set-back temperature.
Some of these parameters are set by the
installer.
Manual
The control of the boiler depends upon the set
room temperature.
OFF
The boiler is switched off. The room
temperature is not displayed and is also not
capable of being modified.
Frost protection (room temperature = 5 °C) is
guaranteed.
Table 4.3 Operating modes of the heating circuit
This is how to do it:
⇒
Turn the left-hand dial.
The operating mode is highlighted.
After a delay of 1 second, you can select the operating
mode.
⇒
Turn the left-hand dial further until the desired
operating mode is displayed.
After a delay of 2 seconds the value is saved and no
longer highlighted..
Th. 12.01.06
11:46
Manual
19.0 °C
> Select operation mode
Fig. 4.9 Changing the operating mode in the default display
Changing the room temperature in the default display
The control of the boiler depends upon the set room
temperature. The controller ensures that the target
room temperature is achieved quickly and is maintained
at this value.
⇒
Turn the right-hand dial.
Instead of the actual room temperature, the target room
temperature is highlighted. After a delay of 1 second,
you can change the target room temperature:
⇒
Turn the right-hand dial further until the desired
room temperature appears.
After a delay of 2 seconds, the new room temperature is
saved, the temperature is no longer highlighted and the
actual room temperature is displayed.
Th. 12.01.06
11:46
Auto
20.5 °C
> Select room temperature
Fig. 4.10 Changing the room temperature in the basic display
The new room temperature is used instead of the
programmed temperature until the end of the current
time programme. This duration depends upon the
operating mode; see also Chapter 4.4.
4.4
Changing the target room temperature
If you change a target value - either the room
temperature or the hot water target value - in the basic
display or in the default display, the new value overrides
the programmed temperatures.
When in „Manual“ mode, the control uses the temporary
temperatures until either the operation mode or the
temperature is changed.
When in „automatic“ mode, the control uses the
temporary temperature until the next time window
starts (if you have changed the set target value outside
a time window) or until the end of the current time
window (if you have changed the set target value within
the time window); see Fig. 4.11.
4 Operation