0020262548_01 Operating instructions

21

Setting level

Values

Unit

Increment, select

Default setting

Min.

Max.

Start

01.01.01

31.12.99

dd.mm.yy

Day.Month.Year

01.01.14

End

01.01.01

31.12.99

dd.mm.yy

Day.Month.Year

01.01.14

Temperature

5

30

1

15

Days at home scheduling

Start

01.01.01

31.12.99

dd.mm.yy

Day.Month.Year

01.01.14

End

01.01.01

31.12.99

dd.mm.yy

Day.Month.Year

01.01.14

Basic settings

Language

Selectable language

English

Basic settings

Date/time

Date

01.01.01

31.12.99

dd.mm.yy

Day.Month.Year

01.01.15

Time

00:00

23:59

h:min

00:10

08:00

Daylight saving time

Manual

,

Auto

Manual

Basic settings

Display

Display contrast

1

15

1

9

Button lock

off

,

On

off

Preferred display

Heating

,

Cooling

,

Vent.

Heating

Basic settings

Costs

Tariff for aux. heater

1

999

1

12

Low-tariff elec. rate

1

999

1

16

High-tariff elec. rate

1

999

1

20

Basic settings

Offset

Room temperature

-3.0

3.0

0.5

0.0

Outside temperature

-3.0

3.0

0.5

0.0

Basic settings

Operating mode

ZONE1

Heating

off

,

Auto

,

Day

,

Set-back

Auto

Cooling

off

,

Auto

,

Day

Auto

1 day at home

Active, Not active

Not active

1 day away from home

Active, Not active

Not active

Ventilation boost

Active, Not active

Not active

Party function

Active, Not active

Not active

Basic settings

Enter zone name

ZONE1

1

10

Let-
ter/number

A to Z, 0 to 9, space

ZONE1

Basic settings

Ventilation

Heat recovery

Auto

,

Activate

,

off

Auto

Basic settings

Max. room air humidity

Max. room air hum.

30

70

%rel

1

40

Basic settings

Default setting

Time programmes

Yes

,

No

No

Содержание VRC 700/6

Страница 1: ...en Operating instructions Weather compensated system control VRC 700 6 0020262548_01 28 11 2022...

Страница 2: ...4 Operation 5 4 1 Operating structure 5 4 2 Basic display 6 4 3 Operating concept 6 5 Operating and display functions 8 5 1 Information 8 5 2 Settings 10 5 3 Operating modes 14 5 4 Advanced functions...

Страница 3: ...physical sensory or mental capabil ities or lack of experience and knowledge if they have been given supervision or instruc tion concerning use of the product in a safe way and understand the hazards...

Страница 4: ...flow temperature of the heating installation If the outdoor temperature increases the system control reduces the flow temperature The system control responds to the fluctuations in the outdoor temper...

Страница 5: ...ine 3 9 CE marking The CE marking shows that the products comply with the basic requirements of the applicable directives as stated on the declaration of conformity The declaration of conformity can b...

Страница 6: ...energy Off Day Set back off Empty line 4 2 3 2 Basic display for the Cooling operating mode Mode Time periods Symbol Information field Auto On Desired cooling temp Off Empty line Day Desired cooling...

Страница 7: ...nge to the Max vent stage Day Set back Direct permanent change to the Max vent stge Night 4 3 1 4 Desired temperature in the Manual cooling advanced function Mode Time periods Effect Activated On Dire...

Страница 8: ...inform ation that provides an overview of the current system status and current settings that you can change there 5 1 1 1 System Menu Information System status Fault status If no maintenance is requ...

Страница 9: ...set the desired set back temperature for the zone Set back temp heat is the temperature that you want to have in the rooms during the night or when you are away from home night mode Menu Information S...

Страница 10: ...e total yield is displayed on the bottom right The highest value achieved in one month for the last two years is dis played in the top right 5 1 2 4 Diagram Reading the electrical consumption Menu Inf...

Страница 11: ...ge 12 You can create up to three time periods for each individual day and for predefined blocks Monday Friday Saturday Sunday Monday Sunday When entering time periods for individual days or blocks the...

Страница 12: ...n Within the time period the circulation is switched on Outside the time period the circulation is switched off 5 2 3 8 Setting the Ventilation time programme Menu Time programmes Ventilation The time...

Страница 13: ...g Button lock Menu Basic settings Display Button lock You can use this function to activate the button lock After one minute of not pressing any button or operating the rotary knob the button lock is...

Страница 14: ...ogrammes or for Everything to the default setting Menu Basic settings Default setting Time pro grammes With Time programmes you reset all the settings you have made in the Time programmes function to...

Страница 15: ...of air using the value that you set in the Max vent stage Day ventilation level Set back The operating mode constantly controls the ex change of air using the value that you set in the Max vent stge N...

Страница 16: ...st The Cylinder boost advanced function heats the water in the domestic hot water cylinder until it reaches the set desired temperature Domestic hot water The advanced function is active for one hour...

Страница 17: ...ears again in the display 7 Care 7 1 Caring for the product Clean the casing with a damp cloth and a little solvent free soap Do not use sprays scouring agents detergents solvents or cleaning agents t...

Страница 18: ...ription of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Fault status Current value N...

Страница 19: ...ast month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total value since start up kWh Fuel Total val...

Страница 20: ...NE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thursday Friday Sat urday Sunday and Monday Friday Saturday Sunday Monday Sunda...

Страница 21: ...Button lock off On off Preferred display Heating Cooling Vent Heating Basic settings Costs Tariff for aux heater 1 999 1 12 Low tariff elec rate 1 999 1 16 High tariff elec rate 1 999 1 20 Basic setti...

Страница 22: ...Fault Heat generator 1 the specific fault code e g F 33 and the specific heat generator appear behind F in the display Heat generator faults 1 Carry out a Reset fault message Page 16 2 If the fault p...

Страница 23: ...basic display 6 Outdoor temperature setting the offset 14 P Party 16 Preventing a malfunction 5 R Reading the article number 5 10 Reading the electrical consumption 10 Reading the environment yield 1...

Страница 24: ...24 Operating instructions 0020262548_01 Time programme 11 quick setting 11 Setting 11 V Ventilation 4 Ventilation boost 16 Ventilation level 11 Z Zone 4 10 Zone in the basic display 6...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...isher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 2191 18 0 Fax 49 2191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyrigh...

Отзывы: