0020262548_01 Operating instructions

11

5.2.1.2 Hot water generation

Danger!
Risk of death from legionella.

Legionella multiply at temperatures below
60 °C.

Have a competent person inform you
about the measures that should be taken
to protect against Legionella in your in-
stallation.

Do not set any water temperatures below
60 °C without consulting the competent
person first.

Menu

Desired temperatures

Domestic hot water

You can set the desired

Domestic hot water

temperat-

ure for the domestic hot water circuit.

If a heat pump is connected and you have set the desired
temperature to above 55 °C, it may be the case that it is the
back-up boiler that predominantly takes on the task of sup-
plying domestic hot water.

5.2.2

Setting the ventilation level

Menu

Ventilation stage

You can use this function to set how quickly the used
room air is replaced with fresh outdoor air.

Max. vent. stage: Day

: The ventilation guarantees quick

exchange of air.

Max. vent. stge: Night

: The ventilation guarantees a re-

duced air change.

5.2.3

Time programme

You can use the time programme to switch the system con-
trol between two implemented settings at specified times.
To do this, create the required time periods in the time pro-
gramme.

Setting the

Heating

time programme (

Page 12)

Setting the

Cooling

time programme (

Page 12)

Setting the domestic hot water circuit time programme
(

Page 12)

Setting the

Circulation

time programme (

Page 12)

Setting the

Ventilation

time programme (

Page 12)

Setting the

High tariff

time programme (

Page 12)

You can create up to three time periods for each individual
day and for predefined blocks (

Monday - Friday

,

Saturday -

Sunday

,

Monday - Sunday

).

When entering time periods for individual days or blocks, the
last information that was entered always applies.

If you have not set any time periods, the system control uses
the time periods set in the factory settings.

Note

Once time programmes are set, they are retained
even if there is a loss of voltage.

5.2.3.1 Heating operating mode example: Time

period for a day

18:00

16:30

22:30

16 °C

21 °C

20:00

A

B

1

3

1

4

2

2

A

Time

B

Temperature

1

Day temp. heating

2

Set-back temp. heat.

3

Time period 1

4

Time period 2

You can specify the temperatures (

Day temp. heating

and

Set-back temp. heat.

) in the Setting the

Desired temperat-

ures

(

Page 10) function.

You can specify the times for the time periods in the Setting
time programmes

Heating

(

Page 12) function.

Day temp. heating

: 21 °C

Set-back temp. heat.

: 16 °C

Period 1:

16:30

18:00

Period 2:

20:00

22:30

Within the time periods, the system control maintains the
room temperature at the set

Day temp. heating

.

Outside of the time periods, the system control maintains the
room temperature at the set

Set-back temp. heat.

.

5.2.3.2 Setting time programmes quickly

If, for example, you require different time periods for just
one working day in the week, first set the times for the entire
block

Monday - Friday

. Then set the different time period for

the working day.

5.2.3.3 Displaying and changing different times in

the block

Monday - Sunday

Period 1:
Period 2:
Period 3:

!! : !! - !! : !!
!! : !! - !! : !!
!! : !! - !! : !!

Back

Select

If you view a block in the display and have defined a different
time period for a day in this block, the display indicates the
time periods in the block with !!.

Содержание VRC 700/6

Страница 1: ...en Operating instructions Weather compensated system control VRC 700 6 0020262548_01 28 11 2022...

Страница 2: ...4 Operation 5 4 1 Operating structure 5 4 2 Basic display 6 4 3 Operating concept 6 5 Operating and display functions 8 5 1 Information 8 5 2 Settings 10 5 3 Operating modes 14 5 4 Advanced functions...

Страница 3: ...physical sensory or mental capabil ities or lack of experience and knowledge if they have been given supervision or instruc tion concerning use of the product in a safe way and understand the hazards...

Страница 4: ...flow temperature of the heating installation If the outdoor temperature increases the system control reduces the flow temperature The system control responds to the fluctuations in the outdoor temper...

Страница 5: ...ine 3 9 CE marking The CE marking shows that the products comply with the basic requirements of the applicable directives as stated on the declaration of conformity The declaration of conformity can b...

Страница 6: ...energy Off Day Set back off Empty line 4 2 3 2 Basic display for the Cooling operating mode Mode Time periods Symbol Information field Auto On Desired cooling temp Off Empty line Day Desired cooling...

Страница 7: ...nge to the Max vent stage Day Set back Direct permanent change to the Max vent stge Night 4 3 1 4 Desired temperature in the Manual cooling advanced function Mode Time periods Effect Activated On Dire...

Страница 8: ...inform ation that provides an overview of the current system status and current settings that you can change there 5 1 1 1 System Menu Information System status Fault status If no maintenance is requ...

Страница 9: ...set the desired set back temperature for the zone Set back temp heat is the temperature that you want to have in the rooms during the night or when you are away from home night mode Menu Information S...

Страница 10: ...e total yield is displayed on the bottom right The highest value achieved in one month for the last two years is dis played in the top right 5 1 2 4 Diagram Reading the electrical consumption Menu Inf...

Страница 11: ...ge 12 You can create up to three time periods for each individual day and for predefined blocks Monday Friday Saturday Sunday Monday Sunday When entering time periods for individual days or blocks the...

Страница 12: ...n Within the time period the circulation is switched on Outside the time period the circulation is switched off 5 2 3 8 Setting the Ventilation time programme Menu Time programmes Ventilation The time...

Страница 13: ...g Button lock Menu Basic settings Display Button lock You can use this function to activate the button lock After one minute of not pressing any button or operating the rotary knob the button lock is...

Страница 14: ...ogrammes or for Everything to the default setting Menu Basic settings Default setting Time pro grammes With Time programmes you reset all the settings you have made in the Time programmes function to...

Страница 15: ...of air using the value that you set in the Max vent stage Day ventilation level Set back The operating mode constantly controls the ex change of air using the value that you set in the Max vent stge N...

Страница 16: ...st The Cylinder boost advanced function heats the water in the domestic hot water cylinder until it reaches the set desired temperature Domestic hot water The advanced function is active for one hour...

Страница 17: ...ears again in the display 7 Care 7 1 Caring for the product Clean the casing with a damp cloth and a little solvent free soap Do not use sprays scouring agents detergents solvents or cleaning agents t...

Страница 18: ...ription of the functions for ZONE1 also applies for all available zones Setting level Values Unit Increment select Default setting Min Max Information System status System Fault status Current value N...

Страница 19: ...ast month kWh Hot water Electricity Total value since start up kWh Fuel Total value since start up kWh Information Consumption History Heating Electricity Total value since start up kWh Fuel Total val...

Страница 20: ...NE1 Cooling Time programmes Circulation Time programmes Ventilation Individual days and blocks Monday Tuesday Wednes day Thursday Friday Sat urday Sunday and Monday Friday Saturday Sunday Monday Sunda...

Страница 21: ...Button lock off On off Preferred display Heating Cooling Vent Heating Basic settings Costs Tariff for aux heater 1 999 1 12 Low tariff elec rate 1 999 1 16 High tariff elec rate 1 999 1 20 Basic setti...

Страница 22: ...Fault Heat generator 1 the specific fault code e g F 33 and the specific heat generator appear behind F in the display Heat generator faults 1 Carry out a Reset fault message Page 16 2 If the fault p...

Страница 23: ...basic display 6 Outdoor temperature setting the offset 14 P Party 16 Preventing a malfunction 5 R Reading the article number 5 10 Reading the electrical consumption 10 Reading the environment yield 1...

Страница 24: ...24 Operating instructions 0020262548_01 Time programme 11 quick setting 11 Setting 11 V Ventilation 4 Ventilation boost 16 Ventilation level 11 Z Zone 4 10 Zone in the basic display 6...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...isher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 2191 18 0 Fax 49 2191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyrigh...

Отзывы: