41
Installation Manual
for VRC 400 weather compensator
Start-up 11
Dial
Test
Test procedure
Press and push
P button for 3
seconds
Heating request
A heating request of 50 °C is simulated. The burner on the
boiler starts up and the pump starts (only up to the maxi-
mum flow temperature of the boiler).
Turn
Hot water request
A hot water request is activated, charging pump starts
working, all other elements are switched off.
Turn
Circulation pump
The circulation pump is activated (if connected). All other
elements are switched off.
Press
Display test
All display elements are displayed.
Press
Software version
The software version is displayed.
Table 11.2