0020244064_02 Operating and installation instructions
11
6
Start-up
1.
For filling the product, see the installation instructions
for the heat generators.
2.
Check that the hydraulic and electric connections are
correctly designed.
3.
Check whether the connections are leak-tight.
4.
Purge your heating installation.
6.1
Purging the product
Validity:
VPS R 100/1 M
1
A
B
C
▶
Open the purging valve
(1)
when filling the heating
circuit with water.
Validity:
VPS R 200/1 B
1
B
C
▶
Open the purging valve
(1)
when filling the heating
circuit with water.
1.
Close the purging valve as soon as water flows out
(repeat this measure several times, if required).
2.
Ensure that the purging connection is leak-tight.
6.2
Thermal insulation of the product
The product comes with thermal-insulation casing.
Significant heat is exchanged at the water connections and
the plugs if these are not thermally insulated.
In heating mode, this heat exchange leads to a reduction in
the heating output and to the temperature level falling.
Note
In cooling mode, this heat exchange leads to a re-
duction in the system output and to the temperat-
ure level rising which, in turn, leads to increased
condensation.
▶
Apply thermal insulation to the water connections, the
outlet plug on the cylinder and all other pipes in order to
limit the heat exchange and therefore reduce the risk of
condensation.
7
Handing the product over to the end
user
▶
Once the installation is complete, answer any questions
that the end user may have.
8
Procuring spare parts
The original components of the product were also certified
by the manufacturer as part of the declaration of conformity.
If you use other, non-certified or unauthorised parts during
maintenance or repair work, this may result in the product no
longer meeting the applicable standards, thereby voiding the
conformity of the product.
We strongly recommend that you use original spare parts
from the manufacturer as this guarantees fault-free and safe
operation of the product. To receive information about the
available original spare parts, contact the contact address
provided on the back page of these instructions.
▶
If you require spare parts for maintenance or repair
work, use only the spare parts that are permitted for the
product.
9
Draining the product
Validity:
VPS R 100/1 M
▶
To drain the product, use the lowest water connection
for the cylinder.
Validity:
VPS R 200/1 B
1
▶
Unscrew the plugs
(1)
to drain the product.
Содержание VPS R 100/1 M
Страница 2: ...2 en Operating and installation instructions 3 en Country specifics 14...
Страница 18: ......
Страница 19: ......