10
Installation instructions for the VPS Buffer Cylinder 0020011995_04
R 1/2"
VL
RL
R 3/4"
Fig. 5.2 Temperature sensor connections and plugs
• Screw the two immersion sensor pockets into the cor-
responding sleeves.
• Blank off the unused sleeves.
• Push the temperature sensors that accompanied the
heat source into the immersion sensor pockets.
Flow sensor at the top, return sensor at the bottom.
• Connect the temperature sensors to the heat source
(see the manual for the heat source).
6 Start-up
Caution!
Risk of damage!
Do not add any antifreeze or corrosion protec-
tion agents to the heating water, as seals can
be damaged as a result and this can lead to
water leaks.
Furthermore it can result in noises during heating mode.
Vaillant assumes no liability for this and such conse-
quential damages. Please inform the user of the proce-
dure for frost protection.
Soften the heating water if the water hardness exceeds
20 °dH. You can use the Vaillant ion exchanger (Part.
No. 990 349) for this purpose. Take note of the manual
accompanying the unit.
Filling and bleeding the buffer cylinder
• Open the plug on the venting sleeve (see Fig. 2.2,
item 13).
• Fill the heating installation with water until the buffer
cylinder has been bled.
• Tighten the plug on the venting sleeve again.
7 Recycling
and
disposal
Both your Valliant VPS buffer cylinder and its associat-
ed packaging consist mainly of recyclable raw materials.
7.1 Unit
Neither the Vaillant buffer cylinder nor any of its acces-
sories belong in the household waste. Make sure the old
unit and any accessories present are disposed of prop-
erly.
7.2 Packaging
The disposal of the transport packaging is undertaken
by the expert technician company that installed the unit.
5 Installation
6 Start-up
7 Recycling and disposal
Содержание VPS 300
Страница 1: ...VPS DE AT CHDEFR BEDEFRNL FR NL DK SE GB ...
Страница 2: ......
Страница 3: ...Für den Fachhandwerker VPS Installationsanleitung Pufferspeicher DE AT CHDE BEDE ...
Страница 15: ...Pour l installateur VPS Notice d installation Ballon tampon CHFR FR BEFR ...
Страница 27: ...Voor de installateur VPS Installatiehandleiding Buffervat NL BENL ...
Страница 39: ...For vvs installatøren VPS Installationsvejledning Bufferbeholder DK ...
Страница 50: ......
Страница 51: ...For the expert technician VPS Installation instructions Buffer Cylinder GB ...
Страница 62: ......
Страница 63: ...För auktoriserade installatörer VPS Installationsanvisning Ackumulatortank SE ...
Страница 74: ......
Страница 75: ......
Страница 76: ...00 2001 1995_04 DEATCH DEFR BE DEFRNL FRNLDKSEGB 082008 ...