9
2 Construction
(Fig. 2.1, page 8)
The housing which accommodates the
special-purpose heating unit is provi-
ded with air slots underneath and at
the front. The air is heated by free
convection without a fan.
The cold air enters the appliance on
the underside, is heated as it flows
past the special heating element and
leaves the heater through the air outlet
grille.
At the rear, the convector is fitted with
a thermostat on which the temperature
can be infinitely selected with a dial.
Please note
•
The room heater must
not
be
installed underneath a wall socket
outlet.
•
The room heater must
not
be
permanently wired to the mains.
•
The appliance must be installed in
the bathroom in such a way that
switches, regulating and control
elements cannot be touched by a
person using the bath or the
shower.
•
Important! The housing temperature
exceeds 60 °C. There is a danger
of fire. See warning notice on the
appliance.
•
Never cover the heater; not even
for a short time!
•
There is a danger of fire. See
warning notice on the appliance.
•
Never mount the appliance directly
next to a curtain, screens or similar
(see fig. 2.2).
V-W 108/0
Fig. 2.2 Wall mounting
V-W 142/0 X
Fig. 3.1 Appliance bracket
6 bracket
7 fixing clips
8 hooking tab
A =
> 10 cm
B =
> 10 cm
C =
> 75 cm
D =
> 20 cm