Fig. 5.1  Starting up

V-W 140/0

Fig. 5.2  Thermostat setting

4 Electrical connection

The appliance must be connected to a
230 V~ supply via the mains plug.
(For the VER 100/3 - VER 200/3).

A PE conductor is not present, since
the appliance is of the totally insulated
type.

The regulations of the local electricity
board must be observed.

The appliance must be installed so
that it can be disconnected from the
supply before any intervention (e. g.
pulling out the mains plug for VER
75/3 - VER 200/3).

The connecting lead is specific to con-
vectors.

Changing the connecting lead must
only be carried out by an approved
contractor.

Only use original Vaillant special-
purpose cables.

5 Starting up

Set the switch (3) to position „

I

”.

The built-in room thermostat keeps the
required room temperature constant.

If a room which is not being used is to
be protected against frost, set the ther-
mostat knob (2) to position (

).

5.1 Switch (3)

The heater is switched off when the O
marking is visible. Involuntary control
is therefore impossible.

The frost protection safeguard is also
switched off at this setting.

5.2 Thermostat setting

Pull the two slides off the room ther-
mostat (fig. 5.1).

Fit the slides at both sides of the stop
according to the temperature/
temperature range.

Position 

approx. 4 °C.

Position 7 approx. 20 °C.

Legend to fig. 5.1 and 5.2

2  Thermostat
3  Switch
9  Slide

10 Case

t   Temperature setting range

Содержание VER 75/3

Страница 1: ...Vaillant Witte Elektro Raumheizer Vaillant Witte Independent Room Heaters VER 75 3 VER 100 3 VER 150 3 VER 200 3 VER 250 3 INSTALLATIONS UND BEDIENUNGSANLEITUNG INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...itial start up only by a qualified contractor Guarantee will only be valid if the appliance has been installed and started up initially by an approved contractor who is responsible for the observance of applicable standards and installation instructions We do not accept responsability for damage arising from the non observance of these instruction 1 Application Universal independant room heaters w...

Страница 3: ... be installed underneath a wall socket outlet The room heater must not be permanently wired to the mains The appliance must be installed in the bathroom in such a way that switches regulating and control elements cannot be touched by a person using the bath or the shower Important The housing temperature exceeds 60 C There is a danger of fire See warning notice on the appliance Never cover the hea...

Страница 4: ...he line connection has to be accessible The installation and electrical connection of the heater must be carried out by an approved skilled person 3 Installation Wall mounting The heater must be mounted vertically see fig 2 1 page 8 Fix the appliance bracket to the wall as shown in the installation sketch fig 3 1 and 3 2 using the enclosed installation materials See fig 3 1 on page 9 for installat...

Страница 5: ...ied out by an approved contractor Only use original Vaillant special purpose cables 5 Starting up Set the switch 3 to position I The built in room thermostat keeps the required room temperature constant If a room which is not being used is to be protected against frost set the ther mostat knob 2 to position 5 1 Switch 3 The heater is switched off when the O marking is visible Involuntary control i...

Страница 6: ... 6206 6207 6208 6209 Anschlußwert 0 75 kW 1 00 kW 1 50 kW 2 00 kW 2 50 kW connected load Spannung 1 N PE 230 V Voltage Frostschutz ca 4 C frost protection Abmessungen Dimensions Höhe height 430 mm 430 mm 430 mm 430 mm 430 mm Breite width 340 mm 420 mm 580 mm 740 mm 900 mm Tiefe depth 85 mm 85 mm 85 mm 85 mm 85 mm Wandabstand 20 mm dist from wall Anschlußkabel 1 m Anschlußkabel 1 m mit Euro Winkels...

Отзывы: