background image

10

Split wall-mounted User Manual

7.8 

TURBO

Press TURBO button during COOL or HEAT mode 
operation. The air rate can be set to HIGH and continue 
to operate for 15 minutes. Press TURBO button again 
twice to release the TURBO mode operation.

7.9 

Special Function Selection

7.9.1  SLEEP function

The COOL, DRY, HEAT, AUTO modes can be set during 
the nighttime hours to reduce the operation sound when 
sleeping, etc..

In order to activate:
With the unit connected (see section 7.4):
•  Press the SLEEP button to reduce the air flow sound 

from the indoor unit.

•  Press the SLEEP button once more to release this 

mode.

The SLEEP mode should only be used at night. If it is 
used uring the day, the cooling/heating capacity will be 
reduced since the room temperature is too high (COOL 
mode).
The unit is operational for a maximum of 24 hours in 
SLEEP mode.

In COOL mode

The ambient temperature gradually increases 2ºC in 
relation to the configured one to ensure that the 
temperature does not drop excessively during sleeping 
hours.

In HEAT mode

The ambient temperature gradually decreases 5ºC in 
relation to the configured one to ensure that the 
temperature does not rise excessively during sleeping 
hours.
-  During the first operating hour of the SLEEP function, 

the ambient temperature will drop 2ºC below the 
configured temperature.

-  Once an hour has elapsed, the temperature will drop 

2ºC more.

-  Once three hours have elapsed, the temperature will 

rise 1ºC.

-  The unit will be operational for a further three hours 

before stopping.

7 Operating Instructions

Содержание V 12-025 W

Страница 1: ...For the user V 12 025 W V 12 035 W V 12 050 W V 12 060 W V 12 060 M2W User Manual Air Conditioner climaVAIR Split Wall Mounted type EN...

Страница 2: ...e COOL 8 7 5 3 Dehumidifying Mode DRY 8 7 5 4 Heating Mode HEAT 9 7 6 Defrosting 9 7 7 Setting the Direction of the Airflow 9 7 7 1 Horizontal Airflow 9 7 7 2 Vertical Airflow 9 7 8 TURBO 10 7 9 Speci...

Страница 3: ...Note The information relating to this unit is divided between two manuals installation manual and user manual Note The appliance is not intended for use by young children or infirm persons without sup...

Страница 4: ...egard to obtaining the CE Marking 5 Description of the Unit This unit is comprised of the following elements Indoor unit Outdoor unit Remote controller Interconnecting services Supplied accessories Fi...

Страница 5: ...d weather Anti freeze All heat pump units will tend to freeze up during the colder winter months the anti freeze function automatically defrosts the outdoor coil as required Anti corrosion casing Outd...

Страница 6: ...nt whilst using insecticides or pesticides These could settle in the unit and harm the health of persons with allergies to specific chemical substances Avoid prolonged direct exposure to cooled air or...

Страница 7: ...n FAN SPEED 6 SLEEP button NIGHT TIME FUNCTION 7 TIMER button START UP TIME 8 TURBO button MAXIMUM FAN SPEED 9 ION button function not available 10 LIGHT button 11 LOCK button 7 2 2 Display Indicators...

Страница 8: ...the LOCK mode press this button again 7 5 Selection of the Operation Mode Press the ON OFF button on the remote controller pointing at the unit press the MODE button to select the needed mode auto co...

Страница 9: ...d by fast defrosting and it does not mean a performance failure Once the unit completes the defrosting process it resumes the heating operation 7 7 Setting the Direction of the Airflow The direction o...

Страница 10: ...the day the cooling heating capacity will be reduced since the room temperature is too high COOL mode The unit is operational for a maximum of 24 hours in SLEEP mode In COOL mode The ambient temperatu...

Страница 11: ...nect automatically Note The automatic connection can only be made with the unit switched off Press the OFF button Press the TIMER button The timer settings range from 1 to 24 hours Each time the TIMER...

Страница 12: ...a i e the walls doors windows ceiling and floor the adjacent rooms are cooler than the room temperature therefore thermal energy is unintentionally lost It is therefore difficult to adequately heat th...

Страница 13: ...es can be caused by the refrigerant circulating inside the unit during operation Cracking noises can be caused by heat expansion or contraction of plastics when the unit is stopped Consult after sales...

Страница 14: ...new If strong odours continue to be a problem contact your after sales service provider to fully deep clean the unit Warning Do not use hot water to clean the filters Warning Do not leave the filters...

Страница 15: ...rant leakage short circuiting or even fire could be caused 12 Product Decommissioning Danger of injury and physical damage When disposing of the product ensure that is done safely and in accordance wi...

Страница 16: ...ant reserves the right to make modifications without prior warning Vaillant Ltd Vaillant House Medway City Estate Trident Close Rochester Kent ME2 4EZ Telephone 0164 292300 Fax 0164 290166 www vaillan...

Отзывы: