12
Installation and maintenance instructions for uniSTOR 0020111105_00
3.2
Technical data
Unit VIH
GB
120/2 S
VIH GB
155/2 S
VIH GB
180/2 S
VIH GB
210/2 S
VIH GB
260/2 S
VIH GB
310/2 S
Total capacity
litres
120
155
180
210
260
310
Actual capacity
litres
119,2
149,1
176,6
211,2
250,3
298,5
Hot water capacity
litres
104,0
136,7
166,4
203,9
247,5
270,5
Maximum supply pressure to pressure reducing valve
MPa (bar)
1,2 (12)
Rated pressure of cylinder
MPa (bar)
0,7 (7)
Maximum operating pressure of heating coil
MPa (bar)
0,35 (3,5)
Operating pressure
MPa (bar)
0,35 (3,5)
Pressure reducing valve
MPa (bar)
0,35 (3,5)
Expansion relief valve
MPa (bar)
0,6 (6)
Temperature and pressure relief valve
°C,
MPa (bar)
90,
0,7 (7)
Charge pressure of hot water expansion vessel MPa (bar)
0,4 (4)
Maximum temperature of heating circuit
°C
85
Maximum temperature of potable hot water
°C
85
Standing heat loss
kW/24 h
1,26
1,53
1,66
1,89
2,07
2,26
Heat up time according to EN 12897
mins
18
23
24
28
35
42
Recovery time (70% capacity)
mins
16
18
17
20
25
30
Primary heat exchanger performance
kW
18,6
18,8
22,0
22,6
22,3
20,4
Flow rate for primary heat exchanger performance
l/min
23,3
Primary heat exchanger pressure drop
mbar
97
97
116
116
116
115
Primary heat exchanger volume
litres
2,94
2,94
3,56
3,56
3,56
3,56
Primary heat exchanger surface area
m
2
0,62
0,62
0,75
0,75
0,75
0,75
Dimensions
Height
mm 1001
1191
1371
1593
1843
2153
Height with hot water draw off
mm
1033
1223
1403
1625
1875
2185
Topple measure
mm
1138
1308
1473
1680
1918
2217
Diameter
mm
554,5
Depth
mm
633
Net weight
kg
26
29
32
36
41
46
Weight (full)
kg
145
177,8
209
248
291
345
Connections
Cold water inlet
22 mm unprofiled pipe (crimp joints)
Hot water draw off
22 mm unprofiled pipe (crimp joints)
Pressure-controlled cold water inlet
22 mm unprofiled pipe (crimp joints)
Secondary return
15 mm unprofiled pipe (crimp joints)
Primary heater flow
22 mm unprofiled pipe (crimp joints)
Primary heater return
22 mm unprofiled pipe (crimp joints)
Primary heating circuit immersion sleeve size
mm
8
Electrical connections
Immersion heater (according to ENBS 60335)
2.7 kW, 230 V, 50 Hz
Length of immersion heater
inch
14
Two port motorised valve
230/240 V, 50 Hz
Cylinder thermostat
230/240 V, 50 Hz
Material data
Cylinder body material
Stainless steel (1.4521)
Cylinder jacket material
Polypropylene
Insulation material
EPS with heat radiation absorber
Insulation thickness
mm
50
Corrosion protection
Stainless steel
Blowing agent for insulation material
Pentane (GWP < 5)
ODP
0
Tab. 3.1 Technical data for uniSTOR domestic hot water cylinder
3 Description of the unit
Содержание uniSTOR
Страница 13: ...i The heat up time is based on a flow rate of 1400 l h at 80ºC Temperature rise from 15ºC to 60ºC ...
Страница 14: ......
Страница 15: ......
Страница 16: ...0020111106_00 GBIE 062011 Subject to change Manufacturer Supplier ...
Страница 53: ...Commissioning checklist and service record ...
Страница 56: ...0020111105_00 GBIE 062011 Subject to change Manufacturer Supplier ...