![Vaillant eloBLOCK VE 12 /14 EU I Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/vaillant/eloblock-ve-12-14-eu-i/eloblock-ve-12-14-eu-i_installation-and-maintenance-instructions-manual_848718023.webp)
Appendix
0020265768_01 eloBLOCK Installation and maintenance instructions
23
Code
Meaning
Remedy
F.073
Fault: Water pressure sensor
Interruption/short circuit of water pressure sensor, interruption/short cir-
cuit to GND in supply line to water pressure sensor or water pressure
sensor defective
F.074
Fault: Water pressure sensor
Water pressure sensor signal outside correct
range (too high)
Line to water pressure sensor has a short circuit to 5 V/24 V or internal
fault in the water pressure sensor
F.075
Fault: Pump/water deficiency
Water pressure sensor and/or pump defective, air in the heating installa-
tion, insufficient water in the product, adjustable bypass
F.159
Short circuit: Outdoor temperature NTC sensor
Short circuit: Outdoor temperature sensor
F.161
Product frozen
Flow rate sensor measures < 3 °C. The fault is automatically reset if T
°C > 4 °C.
No fault is displayed if the sensor is defective.
F.162
Domestic hot water cylinder frozen
Cylinder temperature sensor measures < 3 °C. The fault is automatically
reset if T °C > 4 °C.
No fault is displayed if the sensor is defective.
F.180
Welded relay
The fault is displayed if a welded relay has been detected five times in a
row.
The fault can be deleted by switching the unit on/off.
The electronics saves the fault report in the EEPROM (max. 1
–
5
counter).
A blockage can be eliminated by resetting to factory settings (D.96).
F.181
Contactor completely welded
Welded contactor detected
D
Pump status LED
LED display
Meaning
Cause
Remedy
Lighting up green
Normal operating mode
–
–
Flashing alternately red and
green
Fault
Power supply too low/too high
Overheating
Pump resets automatically once
the fault has been eliminated.
Flashing red
Pump blocked
Pump cannot automatically
reset
Manually reset the pump.
Check the LED.
No display
No power supply
No power supply
Check the power supply.
E
LHM
Code
Meaning
Description
1159
Fault: Outdoor temperature sensor
The outdoor temperature sensor is defective.
1162
Frost: Domestic hot water cylinder
The temperature of the domestic hot water cylinder is too low.
1180
Product limp home mode
The product is in limp home mode. Welded relay