background image

3

Operating manual ecoTEC 0020052777_00

Notes on the documentation 1

1  

Notes on the documentation

The following information is intended to help you 
throughout the entire documentation. 
Further documents apply in combination with this oper-
ating manual.

We accept no liability for any damage caused by non-
observe these instructions.

Other applicable documents

For the owner of the system:
Short operator's manual 

No. 0020040000

For the heating engineer:
Installation and maintenance 
instructions No. 

0020029172 

 or
 No. 

0020029173

Installation manual for flue pipe 

No. 0020046373

  
The manuals for any accessories and controllers used 
also apply.

The Benchmark gas boiler commissioning checklist (in 
the operating instruction manual) should be completed 
by the expert technician and/or by the technician 
present during the commissioning, and handed over to 
the operator of the installation.
If you have any questions, after reading through these 
instructions, considering the operation of the boiler, 
please contact your expert technician or the technical 
department of Vaillant.

1.1  

Storage of documents

Please store this operating manual and other applicable 
documents where they are accessible at all times.
If you move out or sell the appliance, pass on the docu-
ments to the buyer.

1.2  

Symbols used

Please observe the following when operating the unit: 
Safety instructions in this operating instruction manual!

d

 Danger!

Immediate risk of serious injury or death!

H

 Danger!

Danger of burning or scalding!

a

 Caution!

Potentially dangerous situation for the product 
and environment!

h

 Note!

Useful information and instructions.

•  Symbol for a necessary task

1.3 

Validity of the instruction manual

This operating manual applies exclusively to units with 
the following article numbers:

– 0010004139
– 0010004140

For the article number of your unit please refer to the 
identification plate.

1.4 Identification 

plate

The identification plate of the Vaillant ecoTEC is mount-
ed on the underside of the unit and on the rear of the 
electronics box at the factory.

1.5 CE 

label

CE labelling shows that the appliances comply with the 
basic requirements of the applicable directives as stated 
on the data badge.

h

 Note!

Vaillant Ltd. supports the Benchmark Initiative. 
You will find the benchmark gas boiler commis-
sioning checklist in the appendix to these in-
stallation instructions. It is very important 
that this document be filled out properly when 
installing, commissioning and handing-over to 
the operator of the installation.

Содержание ecoTEC SERIES

Страница 1: ...For the owner Operating manual ecoTEC Gas wall boilers with condensing appliance technology VU 466 4 VU 656 4 GB...

Страница 2: ...uctions on operation 6 3 1 Vaillant warranty 6 3 2 Intended use 6 3 3 Requirements of the installation site 6 3 4 Care 6 3 5 Recycling and disposal 6 3 5 1 Appliance 6 3 5 2 Packaging 6 3 6 Energy sav...

Страница 3: ...e documents where they are accessible at all times If you move out or sell the appliance pass on the docu ments to the buyer 1 2 Symbols used Please observe the following when operating the unit Safet...

Страница 4: ...company stand by service from a telephone outside the building If a gas leak is audible leave the building immediately prevent others from entering the building and notify the police and fire brigade...

Страница 5: ...r rent ETCI Regulations for the installation of electrical equipment must also be observed a Caution The unit may only be operated continuously with its cladding properly closed Otherwise under unfavo...

Страница 6: ...r closed hot water central heating installations and for central hot water preparation Any other or additional use is considered to be improper The manufacturer or suppli er is not liable for any resu...

Страница 7: ...s in operation and still the room temperature is not comfortably warm Greater heating comfort and a more practical operating mode is achieved when all rooms in an apartment are heated uniformly and in...

Страница 8: ...ther mostatic valves in the room or specify the minimum temperature at the room thermostat if installed These measures guarantee a sufficient exchange of air and avoid unnecessary cooling and loss of...

Страница 9: ...em Flue problem Only in combination with the vrnetDIALOG As long as this symbol appears in the display the heating feed temperature and hot water outlet temperature are specified by vrnetDIALOG ac ces...

Страница 10: ...1 0 and 2 0bar If the indicator is in the area with the light grey background the system must be topped up with water before starting up see Chapter 4 7 4 hNote The ecoTEC unit is equipped with a pres...

Страница 11: ...the boiler 4 4 1 Setting the hot water temperature 2 3 Fig 4 6 Setting the water temperature Switch on the unit as described in Chapter 4 3 Specify the storage temperature you require using the corre...

Страница 12: ...ng for the heating mode 4 5 1 Setting the flow temperature no controller connected 2 1 Fig 4 8 Setting the flow temperature without a controller If there is no external controller set the flow tempera...

Страница 13: ...ed temperature all the way to the left 4 5 4 Adjusting the room thermostat or weather compensator 2 1 Fig 4 11 Setting a room thermostat or weather compensator Set the room thermostats 1 weather compe...

Страница 14: ...ing installation suffi cient see Chapter 4 2 2 Is there air in the heating installation Is there a fault in the ignition process see Chap ter 4 7 2 Hot water operation no problem Heating does not star...

Страница 15: ...als and diaphragms as well as noises during the heating operation Vaillant assumes no liability for this and such consequential damages To fill up and to re fill the heating system you can nor mally u...

Страница 16: ...stem remains on and the rooms are sufficiently heated while you are away a Caution The frost protection and monitoring systems are only active if the main switch of the unit is in the I position and t...

Страница 17: ...777 d Danger Danger of property damage and personal injury from improper handling Never attempt to perform maintenance or re pairs on the gas wall mounted boiler yourself Assign an approved qualified...

Страница 18: ......

Страница 19: ......

Страница 20: ...0020052777_00 GB 10 2007...

Отзывы: