Appendix
32
Installation and maintenance instructions ecoTEC plus 0020214491_01
Code Parameter
Values or explanations
Default set-
ting
Own setting
D.25
Hot water generation enabled by
eBUS controller
1 = Yes, 0 = No
D.26
Internal accessory relay at X6 (pink
plug)
1 = Circulation pump
2 = Second external pump
3 = Cylinder charging pump
4 = Flue non-return flap/extractor hood
5 = External gas valve
6 = External fault message
2
D.27
Switching accessory relay 1 for
accessory "2-in-7" multi-functional
module
1 = Circulation pump
2 = Second external pump
3 = Cylinder charging pump
4 = Flue non-return flap/extractor hood
5 = External gas valve
6 = External fault message
2
D.28
Switching accessory relay 2 for
accessory "2-in-7" multi-functional
module
1 = Circulation pump
2 = Second external pump
3 = Cylinder charging pump
4 = Flue non-return flap/extractor hood
5 = External gas valve
6 = External fault message
3
D.30
Control signal for gas valve
0 = Off; 1 = On
Not
adjustable
D.33
Fan speed target value
in rpm/10
Not
adjustable
D.34
Fan speed actual value
in rpm/10
Not
adjustable
D.35
Not relevant
Not relevant
D.40
Flow temperature
Actual value in °C
Not
adjustable
D.41
Return temperature
Actual value in °C
Not
adjustable
D.44
Digitalised ionisation voltage
Display field 0 to 102
>80 no flame
< 40 good flame
Not
adjustable
D.47
Outside temperature (with weather
compensator)
Actual value in °C, if the outside temperature sensor is
connected to X41
Not
adjustable
D.50
Offset for minimum speed
in rpm/10, adjustment range: 0 to 300
30
D.51
Offset for maximum speed
in rpm/10, adjustment range: -99 to 0
-45
D.60
Number of temperature limiter shut-
downs
Number of shutdowns
Not
adjustable
D.61
Number of ignition device cutoffs
Number of unsuccessful ignitions in the last attempt
Not
adjustable
D.64
Average ignition time
In seconds
Not
adjustable
D.65
Maximum ignition time
In seconds
Not
adjustable
D.67
Remaining burner anti-cycling time
In minutes
Not
adjustable
D.68
Unsuccessful ignitions at 1st attempt
Number of unsuccessful ignitions
Not
adjustable
D.69
Unsuccessful ignitions at 2nd at-
tempt
Number of unsuccessful ignitions
Not
adjustable
D.70
Not relevant
Not relevant
D.71
Maximum target value heating flow
temperature
40 … 85
℃
75
℃
1.
Five-digit numbers are saved for diagnostics codes 80 to 83. If you select D.80, for example, only the first two digits of the number
will be displayed (e.g. 10). Pressing
switches the display to the last three digits (e.g. 947). In this example, the number of oper-
ating hours for the heating is 10947 hrs. Pressing the
again causes the display to switch back to the diagnostics code that was
called up.